2004
DOI: 10.1016/j.jneumeth.2003.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Design and application of a novel brain slice system that permits independent electrophysiological recordings from multiple slices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 12 publications
0
17
0
1
Order By: Relevance
“…Firstly, the software Notocord ® was employed. So far, in combination with the SliceMaster only Spike2 (Stopps et al, 2004;West et al, 2009; www.ced.co.uk) had been used. Among these software other programs can be utilized for LTP experiments (for an overview see Bortolotto et al, 2001) (Anderson and Collingridge, 2007;www.winltp.com)] and the ones which are customized [for example written with Wave-Metrics' Igor (www.wavemetrics.com) or National Instruments' LabView (www.ni.com)].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Firstly, the software Notocord ® was employed. So far, in combination with the SliceMaster only Spike2 (Stopps et al, 2004;West et al, 2009; www.ced.co.uk) had been used. Among these software other programs can be utilized for LTP experiments (for an overview see Bortolotto et al, 2001) (Anderson and Collingridge, 2007;www.winltp.com)] and the ones which are customized [for example written with Wave-Metrics' Igor (www.wavemetrics.com) or National Instruments' LabView (www.ni.com)].…”
Section: Discussionmentioning
confidence: 99%
“…The system is semi-automated allowing one operator to record simultaneously from an assembly of up to eight brain slices. The system has been described in detail by Stopps et al (2004). Briefly, the SliceMaster used for this report consists of three temperature-controlled integrated brain slice chambers and can be upgraded with five more.…”
Section: Multi Brain Slice Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…recordings from multiple specimen as acute slices or OHSCs (Stopps et al, 2004). The system also could be combined with system integrated microelectrode arrays thus enabling recordings in a sandwich configuration of population activities and in addition, of extracellular and intracellular single unit potentials as well as ion concentrations in particular from tissue regions not accessible from an underlying microelectrode array.…”
mentioning
confidence: 99%