Design and analysis of birefringent SPR based PCF biosensor with ultra-high sensitivity and low loss

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 50 publications
(13 citation statements)
references
References 45 publications
0
10
0
Order By: Relevance
“…The amplitude sensitivity (AS) of the sensor is estimated by using the following equation [41]: SA=1α()λ,ηaα()λ,ηaηa0.25em()RIU1 ${S}_{A}=-\frac{1}{\alpha \left(\lambda ,{\eta }_{a}\right)}\frac{\partial \alpha \left(\lambda ,{\eta }_{a}\right)}{\partial {\eta }_{a}}\,\left({\mathrm{R}\mathrm{I}\mathrm{U}}^{-1}\right)$ where ∂α ( λ , η a ) denotes the variation in confinement loss and α ( λ , η a ) denotes confinement loss.…”
Section: Results Analysis and Discussionmentioning
confidence: 99%
“…The amplitude sensitivity (AS) of the sensor is estimated by using the following equation [41]: SA=1α()λ,ηaα()λ,ηaηa0.25em()RIU1 ${S}_{A}=-\frac{1}{\alpha \left(\lambda ,{\eta }_{a}\right)}\frac{\partial \alpha \left(\lambda ,{\eta }_{a}\right)}{\partial {\eta }_{a}}\,\left({\mathrm{R}\mathrm{I}\mathrm{U}}^{-1}\right)$ where ∂α ( λ , η a ) denotes the variation in confinement loss and α ( λ , η a ) denotes confinement loss.…”
Section: Results Analysis and Discussionmentioning
confidence: 99%
“…The energy received by the optical fiber probe can be attenuated substantially to even render it undetectable in practice. The minimum losses of the sensors and the corresponding resonance wavelengths 36–102 are calculated and shown in Fig. 10.…”
Section: Numerical Resultsmentioning
confidence: 99%
“…The proposed system has a wavelength sensitivity of 1000 and 3750 nm/RIU (refractive index unit), respectively, for two channels and which is suitable for the analysis of chemical and biochemical analytes, including POPs, with refractive indexes in the range of 1.30–1.40. Recently, Islam et al have reported the SPR biosensor with hexagonal lattice photonic crystal fiber (PCF) prepared with stable plasmonic material gold (Au) and a thin film of TiO 2 placed on the glass surface to allure the field from the core guided mode and enhance the adhesion of Au on the fiber [ 105 ]. Both x- and y-polarization planes were investigated and provided with high wavelength sensitivity of 16,000 and 17,000 nm/RIU, respectively, with the overall sensing RI range from 1.33 to 1.41, suitable for the detection of unknown biochemical analytes.…”
Section: Other Types Of Optical Sensors For Popsmentioning
confidence: 99%