Design and analysis of a burst strength device for testing vascular grafts

Abstract: The design and analysis of a device to measure the burst strength (strength under a state of pure radial internal pressure) and compliance of vascular grafts and flexible pressurized tubes is presented. The device comprises three main sections, viz., a clean air-dry pressure controller, a test specimen holder, and automated software for control and data collection. Air pressure is controlled by means of a valve and a dedicated mechanism allowing reaching up to 120 psi in increments of 1 psi, and recording pres… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…The testing device that provides the measurements of burst pressure and compliance is designed and developed in cooperation with the company (Inovenso, Turkey) in accordance with ISO 7198:2016 standard . The burst strength of the vascular graft is described as the pressure at which it fails, and circumferential compliance, which is used as a flexibility or stiffness metric, is expressed as the percentage of diameter change for every 100 mmHg (%/100 mmHg) . Normally, in the case of textile fabrics, the burst strength analysis is often applied in a planar form .…”
Section: Methodsmentioning
confidence: 99%
“…The testing device that provides the measurements of burst pressure and compliance is designed and developed in cooperation with the company (Inovenso, Turkey) in accordance with ISO 7198:2016 standard . The burst strength of the vascular graft is described as the pressure at which it fails, and circumferential compliance, which is used as a flexibility or stiffness metric, is expressed as the percentage of diameter change for every 100 mmHg (%/100 mmHg) . Normally, in the case of textile fabrics, the burst strength analysis is often applied in a planar form .…”
Section: Methodsmentioning
confidence: 99%
“…The burst strength test was conducted using a custom-made piece of equipment designed and manufactured for this type of test [41], as shown in Figure 2c. An 80 mm long vascular graft was pressurized (0.3 psi/s, ~15.5 mmHg/s, for all tests herein) using compressed air.…”
Section: Burst Strengthmentioning
confidence: 99%
“…Both components are positioned at an angle of 30 with respect to the perpendicular axis of the incidence plane. 13 This test allowed direct measurement of burst strength from the average of at least five specimens where the burst strength was defined as the maximum internal pressure at which the SDVGs burst.…”
Section: Burst Strengthmentioning
confidence: 99%