“…Measurements have been carried out in representative working conditions of the investigated drying room, which are different from the ones of conventional DEC cycles for air conditioning purposes. -It has been verified that numerical results of the phenomenological desiccant wheel model, previously developed (De Antonellis et al, 2010) and calibrated (De Antonellis et al, 2015b), were in agreement with the experimental data collected in this work. -Five different control strategies have been defined.…”
Section: Methodssupporting
confidence: 83%
See 2 more Smart Citations
“…Measurements have been carried out in representative working conditions of the investigated drying room, which are different from the ones of conventional DEC cycles for air conditioning purposes. -It has been verified that numerical results of the phenomenological desiccant wheel model, previously developed (De Antonellis et al, 2010) and calibrated (De Antonellis et al, 2015b), were in agreement with the experimental data collected in this work. -Five different control strategies have been defined.…”
Section: Methodssupporting
confidence: 83%
“…The test rig has been deeply described in previous works of the authors (De Antonellis et al, 2015a, 2015b. Air temperature and humidity are controlled through heating coils, cooling coils, evaporative coolers and an electrical heater, while air flow rates are controlled by variable speed fans.…”
Section: Test Facility and Adopted Desiccant Wheelmentioning
confidence: 99%
See 1 more Smart Citation
“…De Antonellis et al [3] studied the humidification process for a hospital application during winter period through an experimental and numerical investigation. Water vapour is adsorbed from outdoor air and it is released through a desiccant wheel to the supply air.…”
Section: Introductionmentioning
confidence: 99%
“…When the ratio process air flow rate to the regeneration air flow rate is greater than 1.3, the desired outlet humidity can be achieved. Besides the lower the outdoor air temperature, the higher the process air flow rate [6]. heating source temperature.…”
Section: Introductionmentioning