2013
DOI: 10.9771/cmbio.v12i1.6429
|View full text |Cite
|
Sign up to set email alerts
|

Desenvolvimento de sistema para reprodução e análise de curvas forçadistensão em tendões calcâneos de ratos

Abstract: <div>Introdução: Embora seja o mais forte dentre os tendões humanos, o tendão calcâneo (TC) é comumente afetado por condições patológicas e/ou traumáticas. Apesar da prevalência e tratamento complexo, a patomecânica da tendinopatia do calcâneo continua desconhecida. Equipamentos capazes de mensurar as propriedades biomecânicas de TCs são indispensáveis em estudos que visam elucidar fatores responsáveis pela tendinopatia ou que influenciem o reparo tecidual. Objetivo: Desenvolver um dispositivo, de baixo … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2019
2019
2019
2019

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 15 publications
0
1
0
1
Order By: Relevance
“…For mechanical testing, specimens of each group (I, n = 6; ID, n = 6; IDL, n = 6; IDE, n = 7; IDEAL, n = 8) were retrieved from the freezer and allowed to thaw at room temperature 6 h before testing, as described elsewhere [27]. Then, soft tissue was removed and ATs were attached to a metal connector (2.5 x 3.5 cm) at each extremity and pinned to a conventional mechanical testing machine equipped with a load cell of 500 N. Tendon thickness and width were measured with a digital caliper and then specimens were pulled to failure at a speed of 0.1 mm/s.…”
Section: Methodsmentioning
confidence: 99%
“…For mechanical testing, specimens of each group (I, n = 6; ID, n = 6; IDL, n = 6; IDE, n = 7; IDEAL, n = 8) were retrieved from the freezer and allowed to thaw at room temperature 6 h before testing, as described elsewhere [27]. Then, soft tissue was removed and ATs were attached to a metal connector (2.5 x 3.5 cm) at each extremity and pinned to a conventional mechanical testing machine equipped with a load cell of 500 N. Tendon thickness and width were measured with a digital caliper and then specimens were pulled to failure at a speed of 0.1 mm/s.…”
Section: Methodsmentioning
confidence: 99%
“…O mecanismo de sinalização celular desencadeado pela matriz fibrosa, denominado de mecanotransdução e sugerido por Vidal (1994), também pode ter atuado de forma mais intensa nos grupos em que foi utilizada a fibrina, pois nesse caso foi observado maior organização das fibras de colágeno. Os dados estruturais não refletiram diretamente na biomecânica, talvez pelo tempo de recuperação, 21 dias, que é marcado por um início do processo de remodelamento (Silva et al, 2013;Tomiosso et al, 2009;Aro et al, 2012;Da Re Guerra et al, 2013).…”
Section: Figurasunclassified