2011 IEEE/PES Power Systems Conference and Exposition 2011
DOI: 10.1109/psce.2011.5772473
|View full text |Cite
|
Sign up to set email alerts
|

Description and technical specifications for generic WTG models — A status report

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
42
0
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(54 citation statements)
references
References 3 publications
1
42
0
1
Order By: Relevance
“…Each DN includes 100 buses, one distribution voltage regulator equipped with LTC, three PhotoVoltaic (PV) units [37], three type-2, two type-3 Wind Turbines (WTs) [38], and 133 loads represented by small induction motors and exponential loads. All the DGs comply with the Low Voltage and Fault Ride Through (LVFRT) requirements, taken from [39].…”
Section: A Test System and Its Two-level Decompositionmentioning
confidence: 99%
“…Each DN includes 100 buses, one distribution voltage regulator equipped with LTC, three PhotoVoltaic (PV) units [37], three type-2, two type-3 Wind Turbines (WTs) [38], and 133 loads represented by small induction motors and exponential loads. All the DGs comply with the Low Voltage and Fault Ride Through (LVFRT) requirements, taken from [39].…”
Section: A Test System and Its Two-level Decompositionmentioning
confidence: 99%
“…These gains are associated with control loops shown in Figs. 1 and 2, and described in [13]. On the synchronous generators side, the participating state variables are the rotor angle δ, the shaft speed ω, the generator field voltage E fd , the generator flux linkage ψ fd and the stabilizer output voltage V st .…”
Section: New Ccbg Oscillatory Modesmentioning
confidence: 99%
“…Notice that CCBGs supply an increasing level of 0%, 2.74% and 13.2% of the total in-service active power generation in cases 2010, 2020 and 2022 respectively. CCBGs are represented in the test bed cases mostly as generic models as described in [13], but there is 6.12% in the 2020 case and 20.22% in the 2022 case of the total in-service CCBG generation represented by General Electric (GE) models [14][15]. Type 3 doubly fed induction generators (DFIG) or DFAG models for representing wind farms and Type 4 full converter control based generators for representing wind farms and utility scale photovoltaic (PV) systems.…”
mentioning
confidence: 99%
“…IgqD is controlled to comply with grid codes. Under the reactive power support control mode, the converter capacity is preferentially used to carry out the reactive power control [25]. IgdD is limited by Imax as follows:…”
Section: Pmsg Transient Behavior Analysismentioning