2002
DOI: 10.1021/ac025712h
|View full text |Cite
|
Sign up to set email alerts
|

Derivatization of Ethinylestradiol with Dansyl Chloride To Enhance Electrospray Ionization:  Application in Trace Analysis of Ethinylestradiol in Rhesus Monkey Plasma

Abstract: The extensive metabolism and administration of low doses of ethinylestradiol (EE) in preclinical animal species necessitates a sensitive analytical method to quantify the drug at low picogram-per-milliliter concentrations in biological matrixes. A highly sensitive and accurate method based on the derivatization of EE with dansyl chloride coupled with liquid chromatography/tandem mass spectrometry is described. The dansyl derivatization of EE introduced a basic secondary nitrogen into the molecule that was read… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
160
1

Year Published

2008
2008
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 183 publications
(166 citation statements)
references
References 39 publications
5
160
1
Order By: Relevance
“…The product ion spectrum of the dansyl derivative of E2 showed the dominant ion of m/z 171 (Fig. 2D), as has been previously observed and assigned to an ion representing the 5-(dimethylamino)naphthyl moiety, formed by homolytic cleavage of the C-S bond between the naphthalene and sulfonyl groups [14,23].…”
Section: Lc-esi-ms/ms Analysis Of Four Aryl-sulfonyl Derivatives Of E2supporting
confidence: 76%
See 3 more Smart Citations
“…The product ion spectrum of the dansyl derivative of E2 showed the dominant ion of m/z 171 (Fig. 2D), as has been previously observed and assigned to an ion representing the 5-(dimethylamino)naphthyl moiety, formed by homolytic cleavage of the C-S bond between the naphthalene and sulfonyl groups [14,23].…”
Section: Lc-esi-ms/ms Analysis Of Four Aryl-sulfonyl Derivatives Of E2supporting
confidence: 76%
“…A major obstacle in steroid analysis by LC-MS and LC-MS/MS had been that many steroids are weakly ionizable in the electrospray ionization (ESI) and atmospheric pressure chemical ionization techniques of LC-MS and LC-MS/MS, leading to low inherent sensitivity. Over the years chemical derivatization techniques have been developed to enhance the ionization of various analytes in LC-MS [11][12][13][14]. The deficiency of poor ionization of steroids in LC-MS has now been largely overcome; a number of derivatization procedures that involve either the introduction of a group carrying a formal charge [15][16][17][18] or the attachment of a group with high proton affinity [14,[19][20][21][22] are now used to enhance ionization efficiency for positive ion detection in steroid analysis by LC-MS and LC-MS/MS.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Derivatization reagents used for LC/ESI‐MS should enhance the ESI response by attaching a readily ionizable group to the original molecule 17, 18. Nevertheless, most of them provide only reagent‐specific ions upon MS/MS fragmentation of the corresponding [M+H] + ions, which usually results in numerous co‐eluting interferences when analyzing complex samples 28…”
Section: Resultsmentioning
confidence: 99%