Derating of power distribution transformers serving nonlinear industrial loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…Derating distribution, industrial, or commercial transformers due to heating induced by harmonics distortion is a well-documented application [35][36][37][38][39]. As defined in Faiz, Ghazizadeh, and Oraee, the four methods applicable to derating transformers include IEEE recommendations, analytical methods, experimental approaches, and finite elements [14].…”
Section: Harmonic Distortion Evaluationmentioning
confidence: 99%
See 2 more Smart Citations
“…Derating distribution, industrial, or commercial transformers due to heating induced by harmonics distortion is a well-documented application [35][36][37][38][39]. As defined in Faiz, Ghazizadeh, and Oraee, the four methods applicable to derating transformers include IEEE recommendations, analytical methods, experimental approaches, and finite elements [14].…”
Section: Harmonic Distortion Evaluationmentioning
confidence: 99%
“…Historically, most system problems caused by harmonic distortion originate at a single source or customer, which prompts mitigation efforts to be directed exclusively at one location, bus, circuit, or subdistribution circuit. In fact, most research endeavors focus on derating transformers rated less than 2 MVA that serve mostly dedicated nonlinear loads [9,[35][36][37][38][39][40][41][42][43]. For substation transformers that serve a combination of residential, industrial, and commercial loads, accounting for harmonic is typically ignored due to the low levels of distortion and isolation of problems [1].…”
Section: Harmonic Distortion Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…The main power quality parameters at the transformer are measured at the machine secondary part (low-voltage windings) with a C.A 8335 Qualistar Plus power quality analyzer [9]. The most import of them are: root mean square (RMS), Total Harmonic Distortion (THD), distorsion factor (DF), crest factor (CF) and Harmonic loss factor (KF) and voltage flicker (PLS) [17][18][19]. According to their values, presented in Figure 9, the transformer operates under normal condition…”
Section: Predictive Maintenance Of a Power Distribution Transformermentioning
confidence: 99%
“…One of the most common power quality issue encountered in the modern electric power grids is the distortion of the current or voltage waveforms. That is mainly caused by the proliferation of the nonlinear loads, which are to be found in any industrial or domestic low-voltage installations [1][2][3]. One could rightly state, that due to the extensive electronic device usage, the linear loads are nowadays increasingly rare.…”
Section: Introductionmentioning
confidence: 99%