Depth-of-Interaction Compensation Using a Focused-Cut Scintillator for a Pinhole Gamma Camera

Abstract: Preclinical SPECT offers a powerful means to understand the molecular pathways of drug interactions in animal models by discovering and testing new pharmaceuticals and therapies for potential clinical applications. A combination of high spatial resolution and sensitivity are required in order to map radiotracer uptake within small animals. Pinhole collimators have been investigated, as they offer high resolution by means of image magnification. One of the limitations of pinhole geometries is that increased mag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…For Ki-67 staining of CAM tissue, the fractional area occupied by the immunoreactive ki-67 was quantified with the Bioquant image analysis system (BIOQUANT Image Analysis Corporation, Nashville, TN) as previously described (22). Random fields from seven independent sections were analyzed per sample and averaged.…”
Section: Methodsmentioning
confidence: 99%
“…For Ki-67 staining of CAM tissue, the fractional area occupied by the immunoreactive ki-67 was quantified with the Bioquant image analysis system (BIOQUANT Image Analysis Corporation, Nashville, TN) as previously described (22). Random fields from seven independent sections were analyzed per sample and averaged.…”
Section: Methodsmentioning
confidence: 99%
“…Different techniques have been studied to alleviate the DoI limitations affecting pinhole SPECT including software-based modeling and corrections, the use of curved fiber bundles to collimate light from a curved scintillator, and the application of a laser processed scintillator with converging pixels. [16][17][18][19] Another possible solution to mitigate this issue and preserve spatial resolution consists of estimating the 3D interaction position. This estimation would be useful for crystals thicker than what is currently available on the market, but it could also be beneficial for already existing gamma cameras.…”
Section: Introductionmentioning
confidence: 99%
“…This may lead to parallax errors for scanner geometries where the ɣ enters the detector under an angle, for example, for diverging, converging or pinhole collimators. Different techniques have been studied to alleviate the DoI limitations affecting pinhole SPECT including software‐based modeling and corrections, the use of curved fiber bundles to collimate light from a curved scintillator, and the application of a laser processed scintillator with converging pixels 16–19 . Another possible solution to mitigate this issue and preserve spatial resolution consists of estimating the 3D interaction position.…”
Section: Introductionmentioning
confidence: 99%
“…Compact, high-resolution gamma imaging cameras are being developed by many research groups (Fiorini et al 2003, Kataoka et al 2005, Vavrik et al 2002, He et al 1999. In a subset of these gamma cameras, micro-columnar CsI(Tl) scintillators are being used in combination with electron multiplication (EM-)CCDs (de Vree et al 2005, Nagarkar et al 2006, Meng 2006, Miller et al 2006, Soesbe et al 2010, Alhassen et al 2011. In such CCD-based detectors, individual scintillation events can be detected in photon counting mode, enabled by readout at high frame rates.…”
Section: Introductionmentioning
confidence: 99%