2019
DOI: 10.1016/j.bspc.2018.12.009
|View full text |Cite
|
Sign up to set email alerts
|

Depolarization spatial variance as a cardiac dyssynchrony descriptor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…Synchromax® is nothing more than a sophisticated non-invasive electrical surface mapping system in which, through the immediate synchrony index (imeSI), a graphical and mathematical processing of the signals originating from the variance of the DII leads (right IV septum) is performed and V6 (left ventricular lateral wall). For this, the software uses the measurement of the electric current flow (volume and direction) and the analysis of agreement of the intrinsicoid deflections of the QRS 6 .…”
mentioning
confidence: 99%
“…Synchromax® is nothing more than a sophisticated non-invasive electrical surface mapping system in which, through the immediate synchrony index (imeSI), a graphical and mathematical processing of the signals originating from the variance of the DII leads (right IV septum) is performed and V6 (left ventricular lateral wall). For this, the software uses the measurement of the electric current flow (volume and direction) and the analysis of agreement of the intrinsicoid deflections of the QRS 6 .…”
mentioning
confidence: 99%
“…However, the identification of those patients who would respond favorably is still uncertain. Computer modeling has shown that the typical LBBB pattern can be a manifestation of slowed conduction velocity in the working myocardium, even when there is no block in the conduction system ( Bonomini et al, 2019 ). Therefore, exploring the correlation between QRS morphological changes and ventricular dyssynchrony can help construct new, noninvasive dyssynchrony biomarkers and provide new, reliable criterion to CRT.…”
Section: Discussionmentioning
confidence: 99%
“…Cardiac electrical dyssynchrony has gained increasing attention in the past decade as an endpoint in cardiac resynchronization therapy (CRT) ( Bonomini et al, 2019 ). However, many studies suggest that using QRS duration as the only criterion to detect dyssynchrony may have limitations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…By these means our method allows to measure the direction of intrinsic cardiac activation, electrical flow and coupling of the intrinsic deflections. Verification of capture of the conduction system and thus physiological pacing is simplified [3]. Synchromax ® ECG analysis allows us to confirm His-Purkinje system capture despite eventually a wider QRS.…”
mentioning
confidence: 99%