Demonstration of a dual alkali Rb/Cs fountain clock

Abstract: We report the operation of a dual Rb/Cs atomic fountain clock. (133)Cs and (87)Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency measurement campaign performed with FO2 in this dual atom clock configuration, including a new determination of the… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
78
0
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 65 publications
(79 citation statements)
references
References 20 publications
0
78
0
1
Order By: Relevance
“…This synthesizer is described in detail in [27]. Figure 5 (upper section, red) highlights the main features.…”
Section: B Fo2-rb Microwave Synthesizermentioning
confidence: 99%
See 2 more Smart Citations
“…This synthesizer is described in detail in [27]. Figure 5 (upper section, red) highlights the main features.…”
Section: B Fo2-rb Microwave Synthesizermentioning
confidence: 99%
“…A dichroic plate in these collimators combines the light at 780 nm with the light at 852 nm for the caesium part of the fountain [27]. The molasses beam diameter (at 1/e 2 ) is 26 mm.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The blue line shows the performance of the Aluminum ion clock [21]. The solid red line shows the performance of a Cesium fountain run in high accuracy mode during a Rubidium vs Cesium comparison [23]. The light red arrow shows the current accuracy of many of the world's best Cesium fountains.…”
Section: New Results From a Cryogenic Cs Fountain Clock At The Nationmentioning
confidence: 99%
“…Bien qu'un maser à hydrogène de bonne qualité, comme ceux dont nous disposons, soit relativement stable et prédictible, nous tirons parti de l'ensemble de fontaines atomiques, étalons primaires et secondaires de fré-quence [4][5][6][7][8] développés au LNE-SYRTE, pour estimer avec exactitude la fréquence du maser à hydrogène utilisé pour réaliser UTC(OP). Le premier bloc de l'algorithme constitue une boucle ouverte du type feed-forward.…”
Section: Premier Bloc : Algorithme De Stabilitéunclassified