1991
DOI: 10.1136/thx.46.4.245
|View full text |Cite
|
Sign up to set email alerts
|

Delivery of propellant soluble drug from a metered dose inhaler.

Abstract: hexamethylpropyleneamine oxime size of the delivery orifice (0-46, 0 61, and prepared by the addition of 5 GBq 9'Tc-0-76 mm internal diameters) and the sodium pertechnetate in 5 ml saline to a phial effect of attaching a spacer were assessed. containing a freeze dried mixture of 0 5 mg Lung deposition was independent of the hexamethylpropyleneamine oxime, 7-6 pg orifice size within the actuator. Without stannous chloride dihydrate, and 4-5 mg the spacer the average dose deposited in sodium chloride (Amersham I… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0
2

Year Published

1992
1992
2012
2012

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(7 citation statements)
references
References 8 publications
(1 reference statement)
1
4
0
2
Order By: Relevance
“…This results in part from the formulation of drug in an ethanolic solution, which evaporates rapidly, leaving many fine droplets in the spray, such that over 10% of the metered dose was contained in droplets small enough to enter the lungs but to be exhaled subsequently. Whole lung deposition values as high as the mean value of 39.7% in this study have also been reported previously for MDI formulations containing a propellant soluble radiolabel, 15,16 which would also comprise rapidly evaporating droplets. When an aqueous solution of fenoterol was delivered by the multidose nebulizer, lung deposition of >30% of the dose was recorded.…”
Section: Discussionsupporting
confidence: 72%
“…This results in part from the formulation of drug in an ethanolic solution, which evaporates rapidly, leaving many fine droplets in the spray, such that over 10% of the metered dose was contained in droplets small enough to enter the lungs but to be exhaled subsequently. Whole lung deposition values as high as the mean value of 39.7% in this study have also been reported previously for MDI formulations containing a propellant soluble radiolabel, 15,16 which would also comprise rapidly evaporating droplets. When an aqueous solution of fenoterol was delivered by the multidose nebulizer, lung deposition of >30% of the dose was recorded.…”
Section: Discussionsupporting
confidence: 72%
“…Además, el espacio que proporciona la cámara entre el ICP y la boca del paciente permite que el aerosol reduzca su velocidad, disminuyendo el choque contra la orofaringe. De este modo se reducen los efectos adversos locales y se aumenta el depósito pulmonar del fármaco 43 . Se ha demostrado que los ICP empleados con cámara de inhalación son tan eficaces como los nebulizadores en el tratamiento de los ataques agudos de asma 44 .…”
Section: Inhaladores Con Cartucho Presurizadounclassified
“…Ele consiste em um reservatório acoplado a uma peça plás-tica, que contém a droga em solução ou em suspensão com surfactantes, lubrificantes e propelentes, a uma pressão de aproximadamente 3 atm, dependendo do tipo utilizado. Os inaladores dosimetrados tradicionais são capazes de gerar uma porcentagem de deposição pulmonar que varia de 10 a 20% 45 .…”
Section: Inaladores Pressurizados Dosimetradosunclassified