1993
DOI: 10.1021/ac00053a022
|View full text |Cite
|
Sign up to set email alerts
|

Dehydrogenase-modified carbon-fiber microelectrodes for the measurement of neurotransmitter dynamics. 1. NADH voltammetry

Abstract: The voltammetry of NADH has been characterized at carbon-fiber microelectrodes at scan rates up to 100 V/s. Electrochemical pretreatment of the electrode dramatically changed the properties of the modified electrode. Anodic pretreatment of the surface resulted in an adsorptive wave for NADH oxidation, while less adsorption was evident under more moderate conditions. The pH of the buffer used for the anodization played a critical role in determining the voltammetric peak shape. Oxidation of NADH at slow scan ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
32
0
1

Year Published

1996
1996
2006
2006

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 60 publications
(36 citation statements)
references
References 10 publications
(1 reference statement)
3
32
0
1
Order By: Relevance
“…102,103 Such developments suggest future directions for carbon nanotube-based devices. Recently, a nanofabricated carbon-based detector (NACAD) has been constructed, capable of measuring the secretion from a single secretory vesicle (the spherical structure that stores transmitters).…”
Section: Modified Carbon Nanotubes For Biosensorsmentioning
confidence: 99%
“…102,103 Such developments suggest future directions for carbon nanotube-based devices. Recently, a nanofabricated carbon-based detector (NACAD) has been constructed, capable of measuring the secretion from a single secretory vesicle (the spherical structure that stores transmitters).…”
Section: Modified Carbon Nanotubes For Biosensorsmentioning
confidence: 99%
“…The output of the lock-in amplifier was passed to an oscilloscope (Model 3 10, Nicolet Instrument Corp., Madison, WI) which then digitized and stored the data. The flow injection anatysis (FIA) apparatus has been described previously [26]. The FIA cell was modified to provide a shorter distance ( < 0.5 cm) between the working and reference electrode.…”
Section: Instrumentationmentioning
confidence: 99%
“…Devido às suas propriedades e características, este tipo de eletrodo tem se tornado uma ferramenta decisiva nas análises e determinações de: (a) contaminantes ambientais 1,2 , (b) moléculas bioquímicas, incluindo medicamentos [3][4][5][6] , (c) metais pesados ou substâncias tóxicas em alimentos [7][8][9] , etc. Além disto, vários processos eletródicos têm sido estudados sob uma nova ótica, originada da utilização dos UME.…”
Section: Introductionunclassified