1992
DOI: 10.2106/00004623-199274070-00008
|View full text |Cite
|
Sign up to set email alerts
|

Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
44
0
1

Year Published

1997
1997
2016
2016

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 109 publications
(46 citation statements)
references
References 0 publications
1
44
0
1
Order By: Relevance
“…The degradation products are reabsorbed by the body. 10 All carriers were used as blocks of 7 × 7 × 10-mm size. Table I shows the physical properties of tested materials, supported by the companies in their data sheets presented.…”
Section: Biodegradable Materialsmentioning
confidence: 99%
“…The degradation products are reabsorbed by the body. 10 All carriers were used as blocks of 7 × 7 × 10-mm size. Table I shows the physical properties of tested materials, supported by the companies in their data sheets presented.…”
Section: Biodegradable Materialsmentioning
confidence: 99%
“…In other studies, a similar response has earlier been observed to PGA and PLLA. 8,27,34,35 Such an osteoconductive reaction seems to be related to, or result from, a walling-off response that creates bony trabeculae to surround the implant. The prior reports describing the osteoconductive properties of PDS are controversial.…”
Section: Discussionmentioning
confidence: 99%
“…In experimental studies in rabbits, PGA screws and rods have been shown to degrade in 24-36 weeks in cancellous bone. 8,27,44 PDS pins have been reported to biodegrade almost fully in the cortical bone of rabbits at 4 months. 45 The degradation time of PLLA, on the other hand, is much longer, a fact known on the basis of both experimental and clinical studies.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Acute synovitis of the knee has been described in three patients after fixation of osteochondral fragments with PGA pins, 5,6 but there was no long-term follow-up. The association between osteolytic changes and foreign-body tissue responses to PGA has been well documented in experimental 20,21 and clinical studies, 8,10,11,22 but the natural history of such lesions is not clear. We have confirmed in our study that there is usually total regression of the osteolysis within three years.…”
Section: Discussionmentioning
confidence: 99%