1990
DOI: 10.1007/bf00183354
|View full text |Cite
|
Sign up to set email alerts
|

Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fractures

Abstract: Cylindrical biodegradable rods of self-reinforced polyglycolide were constructed for internal fixation of fractures in cancellous bone. The self-reinforced texture was achieved by embedding polyglycolide fibres in a polyglycolide matrix. In a prospective clinical study, 62 patients with displaced bimalleolar fractures were managed by open reduction and internal fixation using these rods. The results were assessed between 1.1 and 3.4 years from implantation. One wound infection occurred (1.6%). Five patients (8… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
16
0

Year Published

1992
1992
2023
2023

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 43 publications
(18 citation statements)
references
References 22 publications
2
16
0
Order By: Relevance
“…Development of a radiolucent zone corresponding to the drilling channel, was described by Bostman et al (1990). This was seen in 7 of our cases.…”
Section: Discussionsupporting
confidence: 49%
“…Development of a radiolucent zone corresponding to the drilling channel, was described by Bostman et al (1990). This was seen in 7 of our cases.…”
Section: Discussionsupporting
confidence: 49%
“…They are used for internal fixation of fractures of the malleolus [6,7,11,15,19,21,24,35,39], of the calcaneus [27], of the tibial head [21,25,40), of the talus [21,22,29], instabilities of the glenohumeral joint [23,44], lateral clavicle fractures [21], acromio-clavicular instabilities [21], radial head fractures [21,40], olecranon fractures [21,37,40] fractures [21,40], refixation of flake fractures of the femur, humerus and patella [21,35], humeral condyles [40], patella and distal femur [40] and anterior spondylodesis in cervical interbody fusion by plates and screws [10]. Most of these bioresorbable devices are made of polyglycolid acid (PGA) [21,29,40] or polylactid acid (PLA) [10,11,15,23,27,35,37,40,44] or polydioxanon (PDS) [21]. The Finish group around Rokkanen et al …”
Section: Discussionmentioning
confidence: 99%
“…PLLA has a much longer degradation time than stereo-isomeric forms of PLA, polyglycolide (PGA) and polydioxanone, which are the other biodegradable o~-hydroxy polyester derivatives [35] that have been introduced as implantg for the fixation of fractures [3,4,6,12,25,26,33]. Promising clinical results have been reported in recent years from the use of PLLA implants in faciomaxillary surgery [30], and in more demanding mechanical situations in orthopaedic surgery [21,22,34].…”
Section: Introductionmentioning
confidence: 98%