“…Clinical outcomes published at a median follow-up of 63 months found a local recurrence rate of 1.2 ± 1.2%, comparable to nomogram-based estimates for whole breast irradiation [8]. As the PBSI technique matures, numerous studies in recent literature have investigated how to optimize aspects of the treatment process, including treatment planning [9,10,11,12], training [13,14], clinical practice [15,16], and post-implant analysis [17,18,19,20,21].…”
Section: Purposementioning
confidence: 77%
See 1 more Smart Citation
“…Clinical outcomes published at a median follow-up of 63 months found a local recurrence rate of 1.2 ± 1.2%, comparable to nomogram-based estimates for whole breast irradiation [8]. As the PBSI technique matures, numerous studies in recent literature have investigated how to optimize aspects of the treatment process, including treatment planning [9,10,11,12], training [13,14], clinical practice [15,16], and post-implant analysis [17,18,19,20,21].…”
Section: Purposementioning
confidence: 77%
“…A post-plan was completed on all patients using a similar process to that described by Hilts et al . [17]. Briefly, the post-implant CT scan was deformably registered to the planning CT scan to obtain the CTV contour, which was then reviewed and adjusted as necessary by a radiation oncologist.…”
Section: Methodsmentioning
confidence: 99%
“…A 2 mm skin layer was contoured to calculate the maximum dose to a skin volume of 0.2 cc as a surrogate measure of maximum dose to a 1 cm 2 area (Hilts et al 2015). Additionally, a 2 mm skin contour limited to the PTV skin projection as used during the implantation was created.…”
Section: Brachytherapymentioning
confidence: 99%
“…So far, several commercial registration software, such as Velocity, 15 MIM, 21 and Mirada, 10 have been employed by researchers. The performances of these software in contour propagation have been fully investigated 22 .…”
Section: Introductionmentioning
confidence: 99%