Definition of Metrics to Evaluate Cochlear Array Insertion Forces Performed with Forceps, Insertion Tool, or Motorized Tool in Temporal Bone Specimens

Abstract: Introduction. In order to achieve a minimal trauma to the inner ear structures during array insertion, it would be suitable to control insertion forces. The aim of this work was to compare the insertion forces of an array insertion into anatomical specimens with three different insertion techniques: with forceps, with a commercial tool, and with a motorized tool. Materials and Methods. Temporal bones have been mounted on a 6-axis force sensor to record insertion forces. Each temporal bone has been inserted, wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
26
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(35 citation statements)
references
References 14 publications
(19 reference statements)
1
26
0
Order By: Relevance
“…Since so far microeffects of the insertional procedure were only assumed and described in the literature [Majdani et al, 2010;Nguyen et al, 2014], we tried to objectively quantify those effects in terms of maximum amplitude changes and peak frequency deviation related to ICP. Theoretically it can be assumed that the amplitude of deviation is influenced by the technique (e.g.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Since so far microeffects of the insertional procedure were only assumed and described in the literature [Majdani et al, 2010;Nguyen et al, 2014], we tried to objectively quantify those effects in terms of maximum amplitude changes and peak frequency deviation related to ICP. Theoretically it can be assumed that the amplitude of deviation is influenced by the technique (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…Comparisons of different insertion techniques are, to our knowledge, limited to the measurements of friction force [Majdani et al, 2010] and were focused on the differences between manual, tool and automated insertion techniques [Nguyen et al, 2014]. However, the variations of how to insert an electrode are quite large.…”
Section: Introductionmentioning
confidence: 99%
“…Seven guinea pigs were implanted with the 0.4 electrode array, seven with the 0.4R electrode array and six with the 0.3 electrode array. A linear motorized electrode array insertion tool [ 8 ] carried by a robotic arm [ 11 ] was used to insert the arrays with a constant insertion speed of 0.25 mm/s. The insertion was performed until four electrodes had been placed in the cochlea to ensure a reproducible insertion length (4 mm).…”
Section: Methodsmentioning
confidence: 99%
“…The hammock and frame were designed to decrease respiratory artefacts during measurement of insertion forces. The electrode array was loaded in the insertion tool [ 8 ] which was held by a robotic arm [ 11 ] and was inserted at a constant speed of 0.25 mm/s. The insertion site was sealed with small autologous muscle grafts.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation