2021
DOI: 10.1038/s41598-021-02513-7
|View full text |Cite
|
Sign up to set email alerts
|

Deep learning-based robust automatic non-invasive measurement of blood pressure using Korotkoff sounds

Abstract: This paper proposes a method that automatically measures non-invasive blood pressure (BP) based on an auscultatory approach using Korotkoff sounds (K-sounds). There have been methods utilizing K-sounds that were more accurate in general than those using cuff pressure signals only under well-controlled environments, but most were vulnerable to the measurement conditions and to external noise because blood pressure is simply determined based on threshold values in the sound signal. The proposed method enables ro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…One of the oldest methods that has been the gold standard in clinics for BP measurements in NIBP is to use the auscultatory method [ 157 ], where a cuff is wrapped around a patient’s upper arm and the observer listens to K-sounds, also known as Korotkoff sounds, using a stethoscope and this principle has been applied to automatic BP systems [ 158 , 159 ]. However, a lot of studies have shown that external noises and personnel differences create differences in the BP values [ 160 , 161 , 162 , 163 ].…”
Section: Noninvasive and Artificial Intelligence Based Pressure Measu...mentioning
confidence: 99%
“…One of the oldest methods that has been the gold standard in clinics for BP measurements in NIBP is to use the auscultatory method [ 157 ], where a cuff is wrapped around a patient’s upper arm and the observer listens to K-sounds, also known as Korotkoff sounds, using a stethoscope and this principle has been applied to automatic BP systems [ 158 , 159 ]. However, a lot of studies have shown that external noises and personnel differences create differences in the BP values [ 160 , 161 , 162 , 163 ].…”
Section: Noninvasive and Artificial Intelligence Based Pressure Measu...mentioning
confidence: 99%
“…The CNN was initially proposed for processing images, speech, and time series (2). Guided by the CNN, BP measurements using K-sounds have better accuracy, compared to the automatic oscillometric method.…”
Section: Past and Current States Of Korotkoff-sounds In Clinical Appl...mentioning
confidence: 99%
“…Pan et al used a 10.3389/fcvm.2022.940615 DL method to assess variations in K-sounds (46). Chang et al improved on the former and added the ResNet module for automatic identification of the association between pulse oscillation waves and K-sounds (2). The filtered signal stack can also be used as a picture input.…”
Section: Past and Current States Of Korotkoff-sounds In Clinical Appl...mentioning
confidence: 99%
See 1 more Smart Citation
“…A possible solution is to use AI, and especially deep learning, methods. AI-based methods proposed for NIBP estimation from KSs can be summarized as: (1) methods that ignore the temporal dependencies between the segments derived from KSs [27]- [29] and classify each pulse independent of others; (2) methods that consider the digitized KSs as time series, and estimate BP from sequences of KSs through dealing with a sequence-to-sequence (seq-toseq) classification problem using classification algorithms such as HMM [15], [30] and LSTM-RNN [31].…”
Section: Introductionmentioning
confidence: 99%