2021
DOI: 10.1016/j.jiec.2021.07.015
|View full text |Cite
|
Sign up to set email alerts
|

Deep eutectic solvents synthesis of perovskite type cerium aluminate embedded carbon nitride catalyst: High-sensitive amperometric platform for sensing of glucose in biological fluids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 36 publications
(8 citation statements)
references
References 70 publications
0
8
0
Order By: Relevance
“…Electrochemical impedance spectroscopy (EIS) was adopted to measure the charge transfer resistance ( R ct ) of LGE, Ti 3 C 2 /LGE, S-Ti 3 C 2 /LGE, MoS 2 /LGE, and MoS 2 /S-Ti 3 C 2 /LGE in 0.1 M KCl containing 5 mM Fe­(CN) 6 3–/4– as shown in Figure A. The inset shows Randle’s equivalent circuit, where R ct , R w , R s , and C dl are the charge transfer resistance, Warburg impedance, electrolyte resistance, and double-layer capacitance, respectively . The experimental R ct values were calculated for LGE (380 Ω), Ti 3 C 2 /LGE (270 Ω), S-Ti 3 C 2 /LGE (150 Ω), MoS 2 /LGE (90 Ω), and MoS 2 /S-Ti 3 C 2 /LGE (20 Ω).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Electrochemical impedance spectroscopy (EIS) was adopted to measure the charge transfer resistance ( R ct ) of LGE, Ti 3 C 2 /LGE, S-Ti 3 C 2 /LGE, MoS 2 /LGE, and MoS 2 /S-Ti 3 C 2 /LGE in 0.1 M KCl containing 5 mM Fe­(CN) 6 3–/4– as shown in Figure A. The inset shows Randle’s equivalent circuit, where R ct , R w , R s , and C dl are the charge transfer resistance, Warburg impedance, electrolyte resistance, and double-layer capacitance, respectively . The experimental R ct values were calculated for LGE (380 Ω), Ti 3 C 2 /LGE (270 Ω), S-Ti 3 C 2 /LGE (150 Ω), MoS 2 /LGE (90 Ω), and MoS 2 /S-Ti 3 C 2 /LGE (20 Ω).…”
Section: Resultsmentioning
confidence: 99%
“…The synergetic effects and more reactive sites in MoS 2 /S-Ti 3 C 2 /LGE could explain the increase in peak current. We used the Randles–Sevcik equation , shown in eq to calculate the electroactive surface area (EASA) of MoS 2 /S-Ti 3 C 2 /LGE, MoS 2 /LGE, S-Ti 3 C 2 /LGE, Ti 3 C 2 /LGE, and LGE. where I p and C 0 are the peak current (A) and concentration of the electroactive species (mol cm –3 ), respectively. n is the number of electrons exchanged in the redox process.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…When compared to the proposed conventional methods in section 4 , electrochemical investigations offer important advantages such as ease of design, low cost equipment, high sensitivity and selectivity, accuracy, fewer power requirements, and ease of integration inside microfluidic devices ( Unlüer et al, 2020 ; Cioates, 2020 ). Biosensors and/or electrochemical sensors are widely used in pharmaceutical, environmental, and agricultural studies ( Ganesh et al, 2022a ; Ganesh and Kim, 2022b ; Rajaji et al, 2021 , 2022 ; Kundu et al, 2019 ). Electrochemical transducers are now used in the majority of biosensors because they are simple to create, user friendly, measurement is unaffected by interferences, and need modest reaction volumes.…”
Section: Electroanalytical Methods For Sensing Sars-cov-2mentioning
confidence: 99%