Atmospheric Ozone 1985
DOI: 10.1007/978-94-009-5313-0_72
|View full text |Cite
|
Sign up to set email alerts
|

Decreases in the Ozone and the S02 Columns Following the Appearence of the El Chichon Aerosol Cloud at Midlatitude

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0
1

Year Published

1986
1986
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 1 publication
1
13
0
1
Order By: Relevance
“…The increased SO 2 concentrations are estimated to be of the order of 0.5 to l.Omatmcm, which are also in accordance with the observations of other investigators (23,24,25). On the other hand, Bais et al (26) suggested that the injection of volcanic aerosol into the upper troposphere provides a scavenging mechanism for sulphur dioxide during the first months of 1983. The daily columnar SO 2 measurements in the urban Thessaloniki area ranged from 1.0 to 9.0matm-cm, with mean annual value estimated to be 3.25matm-cm.…”
Section: Instrumentationsupporting
confidence: 74%
“…The increased SO 2 concentrations are estimated to be of the order of 0.5 to l.Omatmcm, which are also in accordance with the observations of other investigators (23,24,25). On the other hand, Bais et al (26) suggested that the injection of volcanic aerosol into the upper troposphere provides a scavenging mechanism for sulphur dioxide during the first months of 1983. The daily columnar SO 2 measurements in the urban Thessaloniki area ranged from 1.0 to 9.0matm-cm, with mean annual value estimated to be 3.25matm-cm.…”
Section: Instrumentationsupporting
confidence: 74%
“…Among these instruments, several Brewer spectrophotometers (Brewer, 1973;Kerr et al, 1985) were deployed at different locations including Thessaloniki, Greece, where the first commercially available singlemonochromator Brewer with serial number 005 (B005) was installed in 1982. Since then B005 has performed continuous measurements of the TOC and the columnar SO 2 (Bais et al, 1993(Bais et al, , 1985Meleti et al, 2012;Zerefos, 1984). These measurements are also used to derive the aerosol optical depth at specific UV-B wavelengths (Kazadzis et al, 2007).…”
Section: Instrumentation and Datamentioning
confidence: 99%
“…Biennial Oscillation (QBO) from the higher latitude stations in the subtropical group. measurements [2 ]. The inverse relationship between total ozone and stratospheric aerosol is shown in Fig.…”
Section: Results and Conclsuionsmentioning
confidence: 98%
“…In presentations at the 1984 Quadrennial Ozone Symposium a number of references were made to unusually low values of columnar ozone observed in 1983 at various locations in the Northern Hemisphere [2,3,8]. A 5-7% decrease in total ozone in both ground based and satellite observations in late 1982 has also been reported [1 ].…”
Section: Introductionmentioning
confidence: 92%