Decomposição dos Antirretrovirais Lamivudina e Zidovudina pelo Processo Fotofenton Assistido no Efluente de Indústria Farmoquímica

Abstract: Os princípios ativos utilizados na formulação de medicamentos compõem os contaminantes presentes na estação de tratamento de indústria farmacêutica. Visando alternativas que levem a soluções eficazes, os processos oxidativos avançados (POA) têm atraído grande interesse da comunidade científica e industrial. Foram realizadas degradações dos antirretrovirais (lamivudina -3TC e zidovudina -AZT), por oxidação, fotodegradação e foto-oxidação, presentes em efluentes de uma indústria farmoquímica do Estado de Goiás. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 2 publications
0
2
0
1
Order By: Relevance
“…Darunavir, lamivudine, and tenofovir have NOEC values below 10 mg/L, which are possible concentrations in a pharmaceutical effluent. Regarding concentration in industrial effluents, the work by Souza et al (2010) shows that the maximum concentrations of zidovudine and lamivudine, which are 6.29 mg/L and 3.22 mg/L respectively, do not come close to the NOECs for these substances.…”
Section: Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…Darunavir, lamivudine, and tenofovir have NOEC values below 10 mg/L, which are possible concentrations in a pharmaceutical effluent. Regarding concentration in industrial effluents, the work by Souza et al (2010) shows that the maximum concentrations of zidovudine and lamivudine, which are 6.29 mg/L and 3.22 mg/L respectively, do not come close to the NOECs for these substances.…”
Section: Resultsmentioning
confidence: 98%
“…High concentrations are expected in industrial effluent treatment plants. A study with real effluents from a zidovudine and lamivudine production plant found drug concentrations of 6.29 mg/L and 3.22 mg/L, respectively (Souza, et al, 2010). Therefore, even if a drug is classified as highly toxic and by the studies currently published, there is an indication that the values of environmental concentrations are low.…”
Section: Resultsmentioning
confidence: 99%
“…A eficiência do processo Fenton depende de alguns parâmetros operacionais: pH, concentrações de H2O2, Fe 2+ e do contaminante, temperatura, composição da matriz (presença de ânions -carbonato/bicarbonato, fosfato, cloreto, sulfato, etc), fonte de radiação e espécie de ferro (SOUZA et al, 2010;BRITO e SILVA, 2012;TROVÓ et al, 2013).…”
Section: Parâmetros Operacionais Do Processo Foto-fentonunclassified