Decentralized Autonomous Hybrid Renewable Power Generation

Abstract: Power extension of grid to isolated regions is associated with technical and economical issues. It has encouraged exploration and exploitation of decentralized power generation using renewable energy sources (RES). RES based power generation involves uncertain availability of power source round the clock. This problem has been overcome to certain extent by installing appropriate integrated energy storage unit (ESU). This paper presents technical review of hybrid wind and photovoltaic (PV) generation in standal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
4

Relationship

2
6

Authors

Journals

citations
Cited by 37 publications
(14 citation statements)
references
References 156 publications
0
9
0
1
Order By: Relevance
“…Literature includes a number of available optimization software tools used for RES based generation [4]. is done in terms of pre and post HOMER analysis as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Literature includes a number of available optimization software tools used for RES based generation [4]. is done in terms of pre and post HOMER analysis as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Power extension of grid to isolated regions is associated with technical and economical limitation. It can be overcome by increasing dependence on RES based generation [4]. It has encouraged exploration and exploitation of RES based decentralized power generation.…”
Section: Introductionmentioning
confidence: 99%
“…Отже, показано перетворення кінетичної енергії від натискання в електричну, але не наведено конкретних технічних рішень для практичного використання цього процесу. В роботі [18] представлена технічний огляд гібридного вітрогенератора і фотоелектричного перетворювача енергії. Ці технічні рішення є досить потужними та громіздкими.…”
Section: аналіз публікаційunclassified
“…Moreover, these harmonic currents adversely affect the operation of circuit breakers, relays, protecting equipments and other sensitive devices. These abnormal conditions results in excessive power losses, reduction in overall efficiency of the power system operation [4][5][6]. Hence it imposes extra burden on the power utility and connected application.…”