2016
DOI: 10.1049/iet-pel.2015.0910
|View full text |Cite
|
Sign up to set email alerts
|

DC‐link current estimation for load‐side converter of brushless doubly‐fed generator in the current feed‐forward control

Abstract: In the stand-alone brushless doubly-fed generator (BDFG) control system, there are two back-to-back converters composed of the machine-side converter (MSC) and the load-side converter (LSC). The LSC is a three-phase AC-DC pulse width modulation converter which usually adopts the double-loop control strategy with outer voltage loop and inner current loop. The introduction of the DC-link current feed-forward for improving the dynamic performance of the LSC can reduce the effect of the load disturbance to the sys… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…Wang and Lin deduced and analyzed the harmonic characteristics of single-phase two-level voltage rectifier in detail. Although only the harmonics of single-phase rectifier were deduced, the theory of power balance of converter used by Wang and Lin still had important reference significance for the study of harmonics of S-phase rectifier [11][12]. Pichan et al proposed a new control strategy of machine-side converter for stator current containing a large number of harmonics in permanent magnet motor.…”
Section: ⅱ Iterature Reviewmentioning
confidence: 99%
“…Wang and Lin deduced and analyzed the harmonic characteristics of single-phase two-level voltage rectifier in detail. Although only the harmonics of single-phase rectifier were deduced, the theory of power balance of converter used by Wang and Lin still had important reference significance for the study of harmonics of S-phase rectifier [11][12]. Pichan et al proposed a new control strategy of machine-side converter for stator current containing a large number of harmonics in permanent magnet motor.…”
Section: ⅱ Iterature Reviewmentioning
confidence: 99%
“…Brushless doubly fed electric generators without brushes and slip rings have superior characteristics, including low maintenance costs and high reliability [1][2][3][4][5][6]. Many scholars and scientific research institutions have studied this topic in the past few years [7][8][9][10][11]. Studies show that these generators outperform conventional brush-geared doubly fed induction generators (DFIGs) in the field of wind power generation [12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…Brushless doubly-fed electric generators with no-slip ring have superior characteristics, including low maintenance costs and high reliability [1][2][3]. Accordingly, many scholars and scientific research institutions have studied this issue in the past few years [4,5]. More specifically, studies show that these generators outperform the conventional brush doubly fed induction generators (DFIG) in the field of wind power generation [6,7].…”
Section: Introductionmentioning