2019
DOI: 10.1016/j.watres.2019.04.030
|View full text |Cite
|
Sign up to set email alerts
|

DBP alteration from NOM and model compounds after UV/persulfate treatment with post chlorination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 69 publications
(36 citation statements)
references
References 54 publications
0
36
0
Order By: Relevance
“…Instead, an extraction–pyrolysis method was used, which has a lower detection limit (0.1 μM as Br). , After laser irradiation, the samples were extracted using methyl tert -butyl ether (MTBE) and analyzed for TOBr and TBM. TOBr was determined using microcoulometry on a total organic halogen (TOX) analyzer (Xplorer, TE Instruments, Netherlands), and TBM was determined on a gas chromatograph (GC, Thermo Fisher Trace 1300) system equipped with an electron capture detector and a HP-5 fused silica capillary column (30 m × 0.25 mm, 0.25 μm, Agilent J&W Scientific), following the United States Environmental Protection Agency (USEPA) Method 551.1. The TBM detection limit is 0.2 nM (0.05 μg L –1 ).…”
Section: Materials and Methodsmentioning
confidence: 99%
“…Instead, an extraction–pyrolysis method was used, which has a lower detection limit (0.1 μM as Br). , After laser irradiation, the samples were extracted using methyl tert -butyl ether (MTBE) and analyzed for TOBr and TBM. TOBr was determined using microcoulometry on a total organic halogen (TOX) analyzer (Xplorer, TE Instruments, Netherlands), and TBM was determined on a gas chromatograph (GC, Thermo Fisher Trace 1300) system equipped with an electron capture detector and a HP-5 fused silica capillary column (30 m × 0.25 mm, 0.25 μm, Agilent J&W Scientific), following the United States Environmental Protection Agency (USEPA) Method 551.1. The TBM detection limit is 0.2 nM (0.05 μg L –1 ).…”
Section: Materials and Methodsmentioning
confidence: 99%
“…The concentrations of TCM were determined according to the USEPA Method 551.1. The samples were extracted using methyl tert -butyl ether (MTBE) and analyzed using a gas chromatograph (Agilent 7890A) system equipped with an electron capture detector and a HP-5 fused silica capillary column (30 m × 0.25 mm, 0.25 mm, Agilent J&W Scientific) . The detection limit of TCM is 0.1 μg L –1 .…”
Section: Methodsmentioning
confidence: 99%
“…•− and Br − reaction was demonstrated. Hua et al [92] studied the DBP alteration from NOM and model compounds after UV/PS treatment and subsequent chlorination. They found that the yields of THMs and dichloroacetonitrile (DCAN) from NOM decreased by 50% and 54%, respectively, after UV/PS followed with chlorination, whereas those of chloral hydrate (CH), 1,1,1trichloropropanone and trichloronitromethane (TCNM) increased by 217%, 136%, and 153%, respectively.…”
Section: Sulfate-radical Processesmentioning
confidence: 99%