Abstract: Abstract. Aiming at the observation data of CORS multi-mode data quality and inspection in CORS station, based on the observation data of a CORS station in Guilin, Guangxi, the paper used TEQC and Anubis software to check the data quality from data utilization, cycle slip ratio and multipath. The results show that the three quality inspection indicators of Anubis software are better than TEQC software, which proves that Anubis' data quality inspection results are effective and reliable. On this basis, using An… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 3 publications
0
1
0
Order By: Relevance
“…The stations used for our study presented effectiveness values greater than 95% in their entirety, likewise, the SNR values turned out to be greater than 30 dBHz for all the stations, which reflects the quality of the signal (according with IGS recommendations (https://igs.org/station-resources/#site-guidelines, accessed on 25 October 2020) and [15]). However, most of the stations present an average multipath value of 0.5 m in MP1 and 0.4 m in MP2 (with values close to those recommended) (Table 1).…”
Section: Resultsmentioning
confidence: 65%
See 1 more Smart Citation
“…The stations used for our study presented effectiveness values greater than 95% in their entirety, likewise, the SNR values turned out to be greater than 30 dBHz for all the stations, which reflects the quality of the signal (according with IGS recommendations (https://igs.org/station-resources/#site-guidelines, accessed on 25 October 2020) and [15]). However, most of the stations present an average multipath value of 0.5 m in MP1 and 0.4 m in MP2 (with values close to those recommended) (Table 1).…”
Section: Resultsmentioning
confidence: 65%
“…For this, various parameters such as precise ephemeris (SP3), orientation parameters of the earth, ocean charge model, among others, were used. Likewise, the North American plate was used as a reference since according to [14], the movements of the GPS sites in Jalisco are better described in relation to this plate than with a global reference frame, since the speeds of the reference site are minimized [15]; thus, the displacements are obtained purely from the phenomenon in question. The Tsview tool, by Thomas Herring, United States of America, complemented the GAMIT/GLOB-K software for GPS time series analysis [16].…”
Section: Methodsmentioning
confidence: 99%
“…The integrity (INT) is theoretically calculated considering the complete observations, and the recommended value is >95% [1]. Cycle slips were calculated from the carrier phase as per the relationship CSR = 1000/(o/slps) [40,41]; where "o/slps" is the number of observations between cycle slips. Theoretically, the recommended value must be less than 1 per 1000 observations [42].…”
Section: Gnss Data Collections Pre-processing and Quality Checkmentioning
confidence: 99%