2018
DOI: 10.1088/1742-6596/1094/1/012007
|View full text |Cite
|
Sign up to set email alerts
|

Data processing in the data acquisition system of the vertical neutron camera plasma diagnostics at the ITER tokamak

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…This result is determined by two components: the relative energy resolution of the spectrometer in the region of the peak (3.25%) and the spread of the alpha particles energy (5%), caused by their scattering in the air gap between the 238 Pu source and the diamond detector. The figure 11 shows the response function to 14 MeV neutrons of the spectrometric path prototype of the data acquisition system of the ITER VNC [9,17], which has the data processing unit identical to the spectrometer considered in this paper. The counting rate during the formation of the specified distribution was ∼1.5 × 10 6 events per second, and the duration of the data collection interval was equal to 20 milliseconds.…”
Section: Test Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…This result is determined by two components: the relative energy resolution of the spectrometer in the region of the peak (3.25%) and the spread of the alpha particles energy (5%), caused by their scattering in the air gap between the 238 Pu source and the diamond detector. The figure 11 shows the response function to 14 MeV neutrons of the spectrometric path prototype of the data acquisition system of the ITER VNC [9,17], which has the data processing unit identical to the spectrometer considered in this paper. The counting rate during the formation of the specified distribution was ∼1.5 × 10 6 events per second, and the duration of the data collection interval was equal to 20 milliseconds.…”
Section: Test Resultsmentioning
confidence: 99%
“…Due to this, for example, according to the Doppler broadening of the line with 8. 4 MeV energy, corresponding to the nuclear reaction 12 C(n, 𝛼) 9 Be, the deuterons and tritons temperature can be determined in the plasma. In experiments with deuterium plasma, the 12 C(n, n ) 12 C channel with 4.4 MeV reaction energy is of particular interest also.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation