2021
DOI: 10.1016/j.rinp.2021.103833
|View full text |Cite
|
Sign up to set email alerts
|

Data on the refractive index of freshly-excised human tissues in the visible and near-infrared spectral range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 15 publications
1
4
0
Order By: Relevance
“…Comparing our data with the human pancreas dispersion published in Ref. [42], which was calculated with only the first two terms in Eq. ( 6), our values within the visible-NIR range are higher, but we need to consider the difference in temperatures between studies.…”
Section: Resultssupporting
confidence: 53%
See 2 more Smart Citations
“…Comparing our data with the human pancreas dispersion published in Ref. [42], which was calculated with only the first two terms in Eq. ( 6), our values within the visible-NIR range are higher, but we need to consider the difference in temperatures between studies.…”
Section: Resultssupporting
confidence: 53%
“…Fig. 6 presents such calculated dispersions for the spectral range of the experimental measurements (401-851 nm), along with some data for pancreas RI as collected from literature [41,42].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, a pair of input values is needed to recover the real and imaginary component. This pair may comprise, for example, the critical angle of attenuated total reflection along with the reflectance at that point (θ c , R c ) [10,11], the pseudo-Brewster angle together with the reflectance at that point (θ B , R B ) [12], or the the pseudo-Brewster angle and the reflectance at normal incidence (θ B , R ⊥ ) [13].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the innovation of this paper lies in highlighting the analysis of the cause of this phenomenon, and trying to create a sensor with excellent performance through a relatively simple structural design. The designed sensor can measure substances with RI of 1.35-1.41 in the NIR band, the RI of the cornea and lens of the human eye are 1.376-1.406 and 1.386-1.406 respectively, and the RI of biological tissues such as lung, liver and spleen varies in the range of 1.38-1.41 [15][16][17]. If the RI change of these biological samples can be accurately measured, it can provide an accurate judgment on the health status of biological tissues [18,19].…”
Section: Introductionmentioning
confidence: 99%