2020
DOI: 10.26434/chemrxiv.13013057
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Data-Driven Many-Body Models with Chemical Accuracy for CH4/H2O Mixtures

Abstract: <div> <div> <div> <p>Many-body potential energy functions (PEFs) based on the TTM-nrg and MB-nrg theoretical/computational frameworks are developed from coupled cluster reference data for neat methane and mixed methane/water systems. It is shown that that the MB-nrg PEFs achieve subchemical accuracy in the representation of individual many-body effects in small clusters and enables predictive simulations from the gas to the liquid phase. Analysis of structural properties cal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(9 citation statements)
references
References 66 publications
(82 reference statements)
0
9
0
Order By: Relevance
“…The first source was normal-mode sampling of the NH 3 -NH 3 optimized dimer which was carried out adopting the same protocol described above for the 1B sets. The second source was scans along the N-N distance of the NH 3 -NH 3 dimer with rigid NH 3 which, as previously found for other molecular systems, 97,98 demonstrate that the MB-nrg PEFs are able to quantitatively reproduce QM reference data, independently of the QM level of theory.…”
Section: B Two-body Pefmentioning
confidence: 61%
See 4 more Smart Citations
“…The first source was normal-mode sampling of the NH 3 -NH 3 optimized dimer which was carried out adopting the same protocol described above for the 1B sets. The second source was scans along the N-N distance of the NH 3 -NH 3 dimer with rigid NH 3 which, as previously found for other molecular systems, 97,98 demonstrate that the MB-nrg PEFs are able to quantitatively reproduce QM reference data, independently of the QM level of theory.…”
Section: B Two-body Pefmentioning
confidence: 61%
“…As shown in previous studies, 92,95,[97][98][99] higher accuracy in modeling 2B energies is achieved by the MB-nrg PEFs that adopt short-range PIPs to effectively represent 2B quantum-mechanical in- teractions that arise from the overlap of the monomers' electron densities (e.g., Pauli repulsion, and charge transfer and penetration). 58,59,61,92,95,97,98,103,105,139 The 2B training (7261 configurations) and test (1449 configurations) sets for the MB-nrg PEFs were generated by including configurations extracted from three different sources. The first source was normal-mode sampling of the NH 3 -NH 3 optimized dimer which was carried out adopting the same protocol described above for the 1B sets.…”
Section: B Two-body Pefmentioning
confidence: 85%
See 3 more Smart Citations