2016
DOI: 10.1103/physrevd.93.122009
|View full text |Cite
|
Sign up to set email alerts
|

Dark matter search results from the commissioning run of PandaX-II

Abstract: We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306×19.1 kg-day was taken, while its dominant 85 Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97×10 −45 cm 2 at a WIMP mass of 44.7 GeV/c 2 … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

5
122
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 93 publications
(127 citation statements)
references
References 37 publications
5
122
0
Order By: Relevance
“…On the resonance, annihilation is very efficient and the couplings and direct detection cross section must be very small. As expected for singlet-doublet scalar dark matter alone [32,33], most of the parameter points are now excluded by PandaX [57,58] (dashed curve) and XENON1T [59] (full curve). Furthermore, they obviously cannot explain the neutrino masses.…”
Section: Random Scansupporting
confidence: 63%
“…On the resonance, annihilation is very efficient and the couplings and direct detection cross section must be very small. As expected for singlet-doublet scalar dark matter alone [32,33], most of the parameter points are now excluded by PandaX [57,58] (dashed curve) and XENON1T [59] (full curve). Furthermore, they obviously cannot explain the neutrino masses.…”
Section: Random Scansupporting
confidence: 63%
“…Both signals are detected in one event by two arrays of photomultiplier tubes (PMTs), located in the top and bottom of the TPC. More detailed descriptions of the PandaX-II experiment can be found in [20][21][22].…”
mentioning
confidence: 99%
“…On the basis of a profile likelihood analysis of all data, an exclusion limit on the spin-independent χN cross section was obtained (Figure 9b). The most stringent limit, 2.5 × 10 −46 cm 2 at a WIMP mass of 40 GeV/c 2 , represents an improvement of more than a factor of 10 from the limit in Reference [49]. In the high-WIMP-mass region, the bounds improve by more than a factor of two over the previous most stringent limit from LUX [56].…”
Section: A Dark Matter Searches With Pandax-i and Pandax-iimentioning
confidence: 76%
“…The upgrade to PandaX-II ( Figure 7b) includes a new low-background steel inner vessel, an increased liquid xenon target mass of 580 kg, and a total of 110 3-inch-diameter PMTs. An additional 48 1-inch-diameter PMTs serve as an active veto in the optically isolated 4-cm liquid xenon region surrounding the outer circumference of the TPC, providing extra power for background rejection [49].…”
Section: A Dark Matter Searches With Pandax-i and Pandax-iimentioning
confidence: 99%
See 1 more Smart Citation