2005
DOI: 10.1088/0031-9155/50/19/017
|View full text |Cite
|
Sign up to set email alerts
|

D-IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in head and neck cancer

Abstract: Dynamic intensity-modulated radiotherapy (D-IMRT) using the slidingwindow technique is currently applied for selected treatments of head and neck cancer at Institute for Cancer Research and Treatment of Candiolo (Turin, Italy). In the present work, a PiXel-segmented ionization Chamber (PXC) has been used for the verification of 19 fields used for four different head and neck cancers. The device consists of a 32 × 32 matrix of 1024 parallel-plate ionization chambers arranged in a square of 24 × 24 cm 2 area. Ea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
34
0
2

Year Published

2009
2009
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(36 citation statements)
references
References 47 publications
0
34
0
2
Order By: Relevance
“…Amerio et al (13) described the design and construction of I'mRT MatriXX, whereas Herzen et al (17) extensively evaluated its dosimetric properties. The clinical application of I'mRT MatriXX has been reported in numerous studies 13 , 15 , 17 , 19 . I'mRT MatriXX is designed to measure doses for beams that are vertical to its front surface; hence, it cannot be used for composite dose verification with multiple gantry angles.…”
Section: Introductionmentioning
confidence: 99%
“…Amerio et al (13) described the design and construction of I'mRT MatriXX, whereas Herzen et al (17) extensively evaluated its dosimetric properties. The clinical application of I'mRT MatriXX has been reported in numerous studies 13 , 15 , 17 , 19 . I'mRT MatriXX is designed to measure doses for beams that are vertical to its front surface; hence, it cannot be used for composite dose verification with multiple gantry angles.…”
Section: Introductionmentioning
confidence: 99%
“…The physical and dosimetric properties of this device have been reported previously 12, 13, 14, 15, 16, 17. The chamber center‐to‐center separation is 0.762 cm, with a sensitive volume of 0.08 cm 3 (0.45 cm in diameter and 0.5 cm in height), covering a 24.4 × 24.4 cm 2 active area.…”
Section: Methodsmentioning
confidence: 86%
“…Validation measurements for the MatriXX 13 , 14 and the MatriXX inclinometer 11 , 15 have previously been performed. For the specific device used in this study, three sets of measurements were performed to validate the device for its specific use in this study.…”
Section: Methodsmentioning
confidence: 99%