1999
DOI: 10.1002/(sici)1521-4109(199907)11:10/11<703::aid-elan703>3.0.co;2-j
|View full text |Cite
|
Sign up to set email alerts
|

Cytochrome C Based Superoxide Sensor for In Vivo Application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
46
0

Year Published

2001
2001
2008
2008

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(48 citation statements)
references
References 23 publications
2
46
0
Order By: Relevance
“…Recently, single component T-COOH momolayers 58 and mixed-monolayers of short alkanethiols 59 with immobilized cyt c gold electrodes have been employed in the electrochemical detection of superoxide radical.…”
Section: ·2 Application To Biosensing Of Metabolismic Materials Inmentioning
confidence: 93%
“…Recently, single component T-COOH momolayers 58 and mixed-monolayers of short alkanethiols 59 with immobilized cyt c gold electrodes have been employed in the electrochemical detection of superoxide radical.…”
Section: ·2 Application To Biosensing Of Metabolismic Materials Inmentioning
confidence: 93%
“…5. The O2 -radical generated in the biopolymer membrane would be electrocatalytically oxidized by 14 ANALYTICAL SCIENCES JANUARY 2001, VOL. 17 the immobilized cyt c to give an anodic current response.…”
Section: Amperometric Measurement Of Superoxide Radical and Sodmentioning
confidence: 99%
“…[1][2][3][4][5][6] Detection of superoxide and SOD has been intensively pursued by spectrophotometric and electrochemical methods. [7][8][9][10][11][12][13][14][15][16] Electrochemical sensors are of great interest due to their advantages, which include microfabrication and in-vivo and in-vitro applications. 17,18 The hemoprotein, cytochrome c (cyt c), undergoes facile reductive reaction with superoxide.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although several electrochemical biosensors for the separate measurement of O 2 •-and H 2 O 2 have been presented (Alpeeva et al, 2005;Campanella et al, 2000Campanella et al, , 1997Emreguel, 2005;Ferapontova et al, 2001;Ge and Lisdat, 2002;Lindgren et al, 2000;Lisdat et al, 1999;McNeil et al, 1995;McNeil and Manning, 2002;Scheller et al, 1999;Shleev et al, 2006), only a limited number of studies describe their simultaneous use (Krylov et al, 2006;Lvovich and Scheeline, 1997;Shipovskov et al, 2004). Furthermore, to our best knowledge simultaneous optical (using LumH 2 ) and electrochemical (using biosensors) monitoring of O 2 •-and H 2 O 2 production by human neutrophil granulocytes has not been performed.…”
Section: Introductionmentioning
confidence: 99%