1995
DOI: 10.1021/ac00103a018
|View full text |Cite
|
Sign up to set email alerts
|

Cyclic Voltammetric Responses for Inlaid Microdisks with Shields of Thickness Comparable to the Electrode Radius: A Simulation of Reversible Electrode Kinetics

Abstract: Given common methods of preparing inlaid microdisk electrodes, shield thicknesses are often comparable to disk radii. Equations appropriate to characterizing the steady state, cyclic voltammetric response for microdisks embedded in in6nite insulating planes poorly approximate the steady state response at these electrodes because, on the time scale to achieve steady state, diffusion around the shield from behind the plane of the electrode contributions to the flux. A finite difference simulation with a nonunifo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
63
1

Year Published

1999
1999
2014
2014

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(72 citation statements)
references
References 0 publications
8
63
1
Order By: Relevance
“…For a microdisc embedded on an infinite insulating plane, as the IS electrode can be regarded (insulating thickness much larger than the electrode radius), k ¼ 4 [24]. For the FS electrode, k depends on the relative dimensions of the thickness of the insulating sheath (b) and the electrode radius [17][18][19][20][21][22]. Approximate analytical equations relating k, b and a were derived by fitting data obtained from numerical procedures [17][18][19]21,22].…”
Section: Electrodes Characterisationmentioning
confidence: 99%
See 3 more Smart Citations
“…For a microdisc embedded on an infinite insulating plane, as the IS electrode can be regarded (insulating thickness much larger than the electrode radius), k ¼ 4 [24]. For the FS electrode, k depends on the relative dimensions of the thickness of the insulating sheath (b) and the electrode radius [17][18][19][20][21][22]. Approximate analytical equations relating k, b and a were derived by fitting data obtained from numerical procedures [17][18][19]21,22].…”
Section: Electrodes Characterisationmentioning
confidence: 99%
“…However, in the CV recorded at the FS electrode, the wave during the backward scan almost exactly retraces that during the forward scan, whereas the CV recorded at the IS displays a larger hysteresis. These results indicate that at the FS electrode the steady state is achieved faster [18,27]. Table 1 summarises relevant voltammetric parameters, includes the thickness of the insulating electrophoretic paint of the FS electrode, which was measured from SEM images, k values and the radii of the two types of electrode, which were calculated from the experimental steady-state limiting current, the other parameters in Eq.…”
Section: Electrodes Characterisationmentioning
confidence: 99%
See 2 more Smart Citations
“…(30). However, at RG < 10 the difference becomes significant due to mediator diffusion from the back of the tip [15,25]. The correction for the finite insulator thickness [24] can be introduced by replacing the factor ''4'' in Eq.…”
Section: Case Ii: Positive Feedback Mode Assuming Finite Insulator Thmentioning
confidence: 99%