2002
DOI: 10.3133/pp1530c
|View full text |Cite
|
Sign up to set email alerts
|

Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota--Analysis of thermal data and nonisothermal modeling of long-term test cycles 1 and 2

Abstract: In May 1980, the University of Minnesota began a project to evaluate the feasibility of storing heated water (150 degrees Celsius) in the Franconia-Ironton-Galesville aquifer (183 to 245 meters below land surface) and later recovering it for space heating. The University's steam-generation facilities supplied hightemperature water for injection. This Aquifer Thermal-Energy Storage system had a doublet-well design in which the injection and withdrawal wells were spaced approximately 250 meters apart. Water was … Show more