2006
DOI: 10.1680/macr.2006.58.10.699
|View full text |Cite
|
Sign up to set email alerts
|

Cyclic behaviour of interior post-tensioned flat plate connections

Abstract: In high seismic regions, post-tensioned (PT) slab–column frames are commonly used to support gravity loads in conjunction with a lateral-force resisting system (LFRS) such as a core wall. The LFRS is designed to resist 100% of the design lateral forces as well as to limit lateral displacements to an acceptable level, whereas the slab–column frame must sustain the gravity loads under the expected (design) displacements. Given the relatively sparse data on the seismic performance of PT flat plate slab–column fra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…Coefficients for the pinching model are calibrated to simulate accurately the actual hysteretic behaviour obtained from previous experiments (Han et al, 2006a). Pinching coefficients of 0 .…”
Section: Connection Modelmentioning
confidence: 99%
See 3 more Smart Citations
“…Coefficients for the pinching model are calibrated to simulate accurately the actual hysteretic behaviour obtained from previous experiments (Han et al, 2006a). Pinching coefficients of 0 .…”
Section: Connection Modelmentioning
confidence: 99%
“…The hysteretic behaviour of the PT slab-column connections reported by Han et al (2006aHan et al ( , 2006bHan et al ( , 2009) is simulated by using the numerical connection model developed by this study. Software OpenSees (2007) is used.…”
Section: Pt Slab-column Connectionsmentioning
confidence: 99%
See 2 more Smart Citations
“…According to ACI 318-05 [1], minimum top bonded reinforcement is required to the PT gravity flat plate system, however, for these PT gravity systems, minimum bottom reinforcement is usually not required in the connection regions. But prior researches [2,3,4,5] indicate that slab bottom reinforcements influenced to lateral drift. The positive slab moment eventually develops on one side of the slab-column connection as the seismic demand is increased, therefore, sufficient bottom reinforcement should be provided to avoid the formation of large cracks.…”
Section: Introductionmentioning
confidence: 99%