Proceedings of the 2005 Particle Accelerator Conference
DOI: 10.1109/pac.2005.1591445
|View full text |Cite
|
Sign up to set email alerts
|

CW Operation of the TTF-III Input Coupler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…However, this coupler, as noted above, was only designed for an average power of ~ 3 kW. The limited power-handling capability, due to excessive heating, was confirmed in tests, first at Rossendorf and then at BESSY, where this coupler is under consideration for the BESSY Free Electron Laser [9]. The Cornell group has made a number of revisions to the TTF-III coupler to reduce its thermal losses.…”
Section: Continuous Wave Couplersmentioning
confidence: 98%
“…However, this coupler, as noted above, was only designed for an average power of ~ 3 kW. The limited power-handling capability, due to excessive heating, was confirmed in tests, first at Rossendorf and then at BESSY, where this coupler is under consideration for the BESSY Free Electron Laser [9]. The Cornell group has made a number of revisions to the TTF-III coupler to reduce its thermal losses.…”
Section: Continuous Wave Couplersmentioning
confidence: 98%
“…Figure 4 shows the S-parameter curves for the optimized test bench in the 1. 25 The errors introduced from the fabrication and installation of the FPCs will lead to the deterioration of transmission matching. A simple and feasible method is to adjust the insertion depth of the antennas to achieve a new matching.…”
Section: Rf Design Of 13 Ghz Fpc Test Benchmentioning
confidence: 99%
“…To minimize risks to the project, the most critical components and technical solutions are tested in the cryomodule under conditions approximating the final CM configuration [25,26]. In this cryogenic test, eight 1.3 GHz superconducting cavities that were previously qualified in a vertical cryostat were fully assembled with all components (FPCs, magnetic shielding, feed-throughs, and tuners) in the cryomodule [27].…”
Section: High Rf Power Conditioning and Operation In Cryomodulementioning
confidence: 99%
“…To confirm the suitability for CW operation, BESSY has already worked on an intensive qualification program. Tests of RF couplers [5] and tuners [6] as well as studies, such as the optimum bath temperature required for reliable and economic CW operation, have been performed. The Horizontal Bi-Cavity Test facility [7] has been set up for this purpose.…”
Section: Accelerationmentioning