2019
DOI: 10.3390/membranes9110145
|View full text |Cite
|
Sign up to set email alerts
|

Custom-Made Ion Exchange Membranes at Laboratory Scale for Reverse Electrodialysis

Abstract: Salinity gradient power is a renewable, non-intermittent, and neutral carbon energy source. Reverse electrodialysis is one of the most efficient and mature techniques that can harvest this energy from natural estuaries produced by the mixture of seawater and river water. For this, the development of cheap and suitable ion-exchange membranes is crucial for a harvest profitability energy from salinity gradients. In this work, both anion-exchange membrane and cation-exchange membrane based on poly(epichlorohydrin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(24 citation statements)
references
References 71 publications
0
23
0
Order By: Relevance
“…Membrane swelling is another essential parameter that may negatively affect the performance of RED because, for instance, the thickness of the membrane may increase its electrical resistance, leading to reduced power output from RED. Despite the fact that swelling degree is often measured as water uptake in literature [36,41], it is worth mentioning that membrane swelling must also be quantified in terms of membrane dimensional changes. Therefore, in this work the effect of swelling on both membrane thickness and diameter is evaluated.…”
Section: Membrane Surface Characterization: Contact Angle Water Uptake Ion Exchange Capacity Fixed Charge Density Swelling and Fourier Atmentioning
confidence: 99%
“…Membrane swelling is another essential parameter that may negatively affect the performance of RED because, for instance, the thickness of the membrane may increase its electrical resistance, leading to reduced power output from RED. Despite the fact that swelling degree is often measured as water uptake in literature [36,41], it is worth mentioning that membrane swelling must also be quantified in terms of membrane dimensional changes. Therefore, in this work the effect of swelling on both membrane thickness and diameter is evaluated.…”
Section: Membrane Surface Characterization: Contact Angle Water Uptake Ion Exchange Capacity Fixed Charge Density Swelling and Fourier Atmentioning
confidence: 99%
“…The details of the different techniques used for the membrane characterization were reported previously [ 19 , 21 ].…”
Section: Methodsmentioning
confidence: 99%
“…The important parameters of the IEM for RED system are the thickness, membrane structure, IEC, areal resistance, and permselectivity, etc. [14][15][16]. Among them, the thickness and structure of the IEM influence critically the performance of the RED system because it affects how ions move smoothly by penetrating the IEM body.…”
Section: Features Of the Conventional Ion Exchange Membranesmentioning
confidence: 99%