2014
DOI: 10.1109/tpwrd.2013.2280300
|View full text |Cite
|
Sign up to set email alerts
|

Current Interruption in Air for a Medium-Voltage Load Break Switch

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 0 publications
1
13
0
1
Order By: Relevance
“…Pada jaringan Loop tertutup, konfigurasi jaringan yang digunakan adalah Jaringan Spindel dengan melakukan beberapa perubahan, di antaranya merubah peralatan proteksi yang semula menggunakan Overcurrent dan Ground Fault relay menjadi line Differential Relay [14], yang posisinya diletakkan pada kubikel pelanggan sisi incoming dan outgoing. Karena pada kubikel pelanggan telah dipasang relay differential pada sisi incoming dan outgoing, maka Load Break Switch LBS [10] pada sisi Incoming dan Outgoing harus diganti juga dengan Circuit Breaker (CB), seperti pada gambar berikut: Perubahan berikutnya adalah pada gardu hubung jaringan spindel yang semula menggunakan LBS dengan posisi LBS terbuka saat kondisi normal, pada sistem loop tertutup LBS digantikan…”
Section: Pembahasan 31 Perubahan Jaringan Dari Spindel Ke Close Loopunclassified
“…Pada jaringan Loop tertutup, konfigurasi jaringan yang digunakan adalah Jaringan Spindel dengan melakukan beberapa perubahan, di antaranya merubah peralatan proteksi yang semula menggunakan Overcurrent dan Ground Fault relay menjadi line Differential Relay [14], yang posisinya diletakkan pada kubikel pelanggan sisi incoming dan outgoing. Karena pada kubikel pelanggan telah dipasang relay differential pada sisi incoming dan outgoing, maka Load Break Switch LBS [10] pada sisi Incoming dan Outgoing harus diganti juga dengan Circuit Breaker (CB), seperti pada gambar berikut: Perubahan berikutnya adalah pada gardu hubung jaringan spindel yang semula menggunakan LBS dengan posisi LBS terbuka saat kondisi normal, pada sistem loop tertutup LBS digantikan…”
Section: Pembahasan 31 Perubahan Jaringan Dari Spindel Ke Close Loopunclassified
“…In the cases where the test switch fails to interrupt, the laboratory circuitbreaker terminates the experiment. Further information on the laboratory circuit and setup, including photographs of the test rig and circuit components can be found elsewhere [6], [12].…”
Section: Test Object Dimensions and Materialsmentioning
confidence: 99%
“…In a previous study, a simple MV load break switch design where air is blown axially onto the arc was investigated with the objective of determining the influence of different design parameters on its current interrupting capability [6]- [9]. The present work compares the efficiency of such a straight axial flow design with two other flow concepts, namely a radial flow (also referred to as stagnation point flow) and a swirling axial flow, all by using simplified MV load break switch geometries in atmospheric, room temperature ambience.…”
Section: Introductionmentioning
confidence: 99%
“…Although there are plenty of studies on the current interruption in high-voltage (HV) gas circuit breakers [31][32][33], vacuum interrupters [34], and medium voltage load breakers [35][36][37], only a few reviews on the low-speed load break switches, mostly relying on experimental findings without MHD simulations [38,39], are available. Just a few studies deal with simulations for VCB [40] and air breakers at a contact speed of about 2.5 m/s [33], which will result in a short gap before the CZ.…”
Section: Introductionmentioning
confidence: 99%