2016 7th India International Conference on Power Electronics (IICPE) 2016
DOI: 10.1109/iicpe.2016.8079413
|View full text |Cite
|
Sign up to set email alerts
|

Current harmonics reduction of three phase grid connected pulse width modulated voltage source inverter by hysteresis current controller with offset band

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…Hysteresis control strategy need high sampling frequency and high-order harmonics. 8 In recent years, various high quality control strategies have been proposed by experts and scholars, among which the model predictive direct power control strategy is simple and easy to be implemented. Main Abbreviations in this paper is summarized in Table 1.…”
Section: Introductionmentioning
confidence: 99%
“…Hysteresis control strategy need high sampling frequency and high-order harmonics. 8 In recent years, various high quality control strategies have been proposed by experts and scholars, among which the model predictive direct power control strategy is simple and easy to be implemented. Main Abbreviations in this paper is summarized in Table 1.…”
Section: Introductionmentioning
confidence: 99%
“…In general hysteresis current controller (HCC) is implemented as the current controller because it provides fast response, good accuracy and it is implementation in practical application is quite simple [6]. Along with the above advantage it's also has disadvantages like it is not capable to use the zero output state of single phase inverter which can be used to improve the output voltage waveform, the output voltage is switched from +VDC to -VDC to control the output current to be still in the band hence the nature of the output voltage is bipolar in nature which result in higher in higher harmonic content, it also exhibits high switching frequency [7]. The discussed disadvantages of the HCC like incapability of using zero output state and bipolar nature of output voltage can be overcome by using double band hysteresis current controller.…”
Section: Introductionmentioning
confidence: 99%
“…The THD of the output is another important index that can reflect good performance of the three-phase VSI. A high THD will degrade the current quality and lead to the overheating of the equipment [15].Therefore, decreasing the THD is another goal that researchers are pursuing [16,17]. For this purpose, a seven-segment technique of SVPWM will be chosen to determine the switching sequence because of the low THD.…”
Section: Introductionmentioning
confidence: 99%