2009
DOI: 10.1109/tie.2009.2022070
|View full text |Cite
|
Sign up to set email alerts
|

Current Harmonic Compensation by a Single-Phase Shunt Active Power Filter Controlled by Adaptive Neural Filtering

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
59
0
2

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 150 publications
(64 citation statements)
references
References 27 publications
2
59
0
2
Order By: Relevance
“…The SRF-based algorithm works by changing a fundamental positive sequence current into direct current by Park Transform, then filtering out the harmonic and reactive current through a low-pass filter (LPF), and finally getting the compensation current reference value [16], as shown in Figure 2.…”
Section: Basic Idea Of Srf-based Harmonic Detection Algorithmmentioning
confidence: 99%
See 1 more Smart Citation
“…The SRF-based algorithm works by changing a fundamental positive sequence current into direct current by Park Transform, then filtering out the harmonic and reactive current through a low-pass filter (LPF), and finally getting the compensation current reference value [16], as shown in Figure 2.…”
Section: Basic Idea Of Srf-based Harmonic Detection Algorithmmentioning
confidence: 99%
“…It is urgent to search a method that could detect the random harmonic current or voltage in load and then compensate them according to actual demands. At present, the main methods for harmonic detection and compensation are classified as Filter method [13], Wavelet Transform method [14], Neural Network method [15,16], FFT method [17,18], PQ method [19], and SRF method [20]. The authors have deeply studied these methods by reading a large number of literatures [21][22][23][24][25][26][27] and evaluated them from computation, response speed, reliability, and compensation precision.…”
Section: Introductionmentioning
confidence: 99%
“…Some of these methods [1], [2] require the information of the fundamental component of the grid voltage to extract the harmonics present in the source current. The grid voltage is likely to contain distortions, including multiple zero crossings, and the service of a phase-locked loop (PLL) is employed to extract the fundamental component of the grid voltage.…”
Section: Iiliterature Surveymentioning
confidence: 99%
“…In filter design and its application, the methods for extraction of the harmonics from line current and determination of the filter reference current play an important and crucial role. Indeed, accuracy and speed of the SAF response are related to this point [9][10][11]. Time domain and frequency domain are two well-known methods for generation of reference current [12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…This fact is proved with mathematical equations. With regard to the compensation objectives, the control strategy and the method for extracting the nonactive load currents references are determined [8][9][10][11][12][13][14][15]. The purpose of this paper is to compensate the harmonic current using the frequency domain method of compensation in which all harmonic current components are targeted and eliminated.…”
Section: Introductionmentioning
confidence: 99%