2021
DOI: 10.1111/pan.14104
|View full text |Cite
|
Sign up to set email alerts
|

Cuffed endotracheal tubes in neonates and infants of less than 3 kg body weight—A retrospective audit

Abstract: Background Large prospective clinical studies have shown that modern cuffed pediatric tracheal tubes can be used safely, even in children weighing ≥3 kg. There is a growing interest in their use in children weighing <3 kg so that they, too, can benefit from the potential advantages, particularly the high probability of these tubes fitting into and sealing the pediatric airway at the first intubation attempt. This study aimed to find a cut‐off body weight for procedures requiring a cuffed tracheal tube to seal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 25 publications
0
1
0
Order By: Relevance
“… 64 , 65 In those infants weighing 2–3 kg, cuffed tubes may be chosen in >50% of occasions at ≥2.7 kg weight. 11 , 66 Reportedly, a 2.5 mm ID Mircocuff tube is currently under development. 11 …”
Section: Discussionmentioning
confidence: 99%
“… 64 , 65 In those infants weighing 2–3 kg, cuffed tubes may be chosen in >50% of occasions at ≥2.7 kg weight. 11 , 66 Reportedly, a 2.5 mm ID Mircocuff tube is currently under development. 11 …”
Section: Discussionmentioning
confidence: 99%
“…64,65) . 2-3 kg 환자 대상 연구 에 따르면, 2.7 kg 이상 환자 삽관 시 CETT가 50% 이상 쓰였다 11,66) . 본 종설 작성 당시, 2.5 mm Microcuff TM 관…”
Section: 주의사항unclassified
“…10,57,60 Experts and learners advocate for feedback to be timely, which increases the likelihood that the feedback will be used for improvement. [3][4][5][6][7]20,26,28,30,52,54,63 While finding time to provide feedback during clinical work can be a challenge, 46,[64][65][66][67] realtime feedback has been shown to improve performance. 68,69 Additionally, there is literature to support that real-time, workplace-based assessments provide more specific and effective feedback than end-of-rotation evaluations.…”
Section: Giving Feedback Components and Characteristics Of High-quali...mentioning
confidence: 99%
“…64,65 In those infants weighing 2-3 kg, cuffed tubes may be chosen in >50% of occasions at ≥2.7 kg weight. 11,66 Reportedly, a 2.5 mm ID Mircocuff tube is currently under development. 11…”
Section: Three Caveatsmentioning
confidence: 99%