2018
DOI: 10.1016/j.jvir.2017.10.004
|View full text |Cite
|
Sign up to set email alerts
|

CT-Guided Fine-Needle Aspiration Biopsy of Pulmonary Nodules 8 mm or Less Has a Higher Diagnostic Accuracy than Positron Emission Tomography–CT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…The SERS EpCAM-aptasensors sensitively discriminated the tumor with a volume of 23.471 mm 3 from normal tissue. Such a tumor detection sensitivity of our biosensor is comparable to the average tumor diameter of 8 mm detected by wide-used CT imaging in the clinic . The receiver operating characteristic (ROC) curve exerted a sensitivity/specificity of 0.9411 for tumor-bearing mice over controls (Figure d), suggesting that the SERS EpCAM-aptasensors are excellent classifiers as they specifically detect the exosome levels in plasma.…”
Section: Resultsmentioning
confidence: 59%
See 1 more Smart Citation
“…The SERS EpCAM-aptasensors sensitively discriminated the tumor with a volume of 23.471 mm 3 from normal tissue. Such a tumor detection sensitivity of our biosensor is comparable to the average tumor diameter of 8 mm detected by wide-used CT imaging in the clinic . The receiver operating characteristic (ROC) curve exerted a sensitivity/specificity of 0.9411 for tumor-bearing mice over controls (Figure d), suggesting that the SERS EpCAM-aptasensors are excellent classifiers as they specifically detect the exosome levels in plasma.…”
Section: Resultsmentioning
confidence: 59%
“…Such a tumor detection sensitivity of our biosensor is comparable to the average tumor diameter of 8 mm detected by wide-used CT imaging in the clinic. 47 The receiver operating characteristic (ROC) curve exerted a sensitivity/specificity of 0.9411 for tumor-bearing mice over controls (Figure 3d), suggesting that the SERS EpCAMaptasensors are excellent classifiers as they specifically detect the exosome levels in plasma. To surveil the postoperative tumor recurrence, we performed the surgical resection on the mice and then detected plasma exosomes every week after surgical resection.…”
mentioning
confidence: 98%
“…For small lung nodules, the diagnostic accuracy increases with increasing nodule size. In a small retrospective study of 43 FNA biopsies of sub-8 mm nodules, Suresh et al found a diagnostic accuracy of 81.4% and sensitivity of 88.9%, significantly higher than those of PET-CT alone which had an accuracy of 46.5% and sensitivity of 38.9%, P<0.001 (33). In another retrospective review of 117 core biopsies of nodules measuring 8 mm or less, Zhao et al reported a higher diagnostic accuracy, sensitivity, and specificity of 95.7%, 95.8%, and 95.5% respectively (34).…”
Section: Diagnostic Accuracymentioning
confidence: 95%
“…Provenance and Peer Review: This article was commissioned by the Guest Editors (Scott Swanson, Daniel Dolan) for the series "How to Evaluate, Diagnose and Treat Small Lung Nodules" published in Current Challenges in Thoracic Surgery. The article has undergone external peer review.Peer Review File: Available at https://dx.doi.org/10.21037/ ccts-[21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] …”
mentioning
confidence: 99%