2019
DOI: 10.1017/s1431927619005725
|View full text |Cite
|
Sign up to set email alerts
|

CryoTEM with a Cold Field Emission Gun That Moves Structural Biology into a New Stage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
41
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
3
2

Relationship

2
7

Authors

Journals

citations
Cited by 51 publications
(42 citation statements)
references
References 3 publications
1
41
0
Order By: Relevance
“…Currently, cryo-EM structures with resolutions in the range of 3-4 Å are common 44 . Resolutions in the range of 1.5-2 Å, however, have been restricted to standard benchmark proteins, such as apo-ferritin 22,45 and β-galactosidase 46 , and other highly symmetric samples, including an adeno-associated virus serotype 2 (AAV2) icosahedral capsid variant 47 , the dodecameric urease from Y. enterocolitica 48 and sheep lens connexin 28 .…”
Section: Discussionmentioning
confidence: 99%
“…Currently, cryo-EM structures with resolutions in the range of 3-4 Å are common 44 . Resolutions in the range of 1.5-2 Å, however, have been restricted to standard benchmark proteins, such as apo-ferritin 22,45 and β-galactosidase 46 , and other highly symmetric samples, including an adeno-associated virus serotype 2 (AAV2) icosahedral capsid variant 47 , the dodecameric urease from Y. enterocolitica 48 and sheep lens connexin 28 .…”
Section: Discussionmentioning
confidence: 99%
“…(c) FSC curves: gold standard masked half-maps (black) and map versus model (red). refinement compared with other very high-resolution reconstructions of mouse heavy-chain apoferritin obtained with CRYO ARM 300 (Kato et al, 2019). Nevertheless, despite the low particle density, sub-2 Å resolution reconstruction was still possible.…”
Section: Figurementioning
confidence: 92%
“…There is some utility in comparison of our results to far superior ones of the same complex obtained elsewhere, such as EMD-9599 (Danev et al, 2019), EMD-9865 (Kato et al, 2019) in the electron microscopy data bank (EMDB), as they were acquired using equipment providing the very highest performance possible for cryo-EM SPA. The 1.75 Å map of apoferritin (Wu et al, 2020) from a 200KV microscope further demonstrates the possibilities with increased quantities of data when coupled to optimal grids, sample preparation technique and microscope stability.…”
Section: Discussionmentioning
confidence: 86%
“…Developments contributing to advances in SPA have been mainly improvements of electron microscope performance (Knapek et al, 1982; Morishita et al, 2013), developments of electron beam direct detectors (Bammes et al, 2012; McMullan et al, 2016), methods for three-dimensional structure reconstructions (Grant et al, 2018; Kimanius et al, 2016; Punjani et al, 2017; Zivanov et al, 2018), and automated acquisition via Leginon (Carragher et al, 2000), SerialEM (Mastronarde, 2005) or manufacturer software. In recent years, close to atomic resolution has been achieved (Bartesaghi et al, 2015; Danev et al, 2019; Kato et al, 2019) which permits construction of atomic models without foreknowledge of the protein sequence.…”
Section: Introductionmentioning
confidence: 99%