Cryogenic absolute radiometers as laboratory irradiance standards, remote sensing detectors, and pyroheliometers

Abstract: The dramatic improvement in heat diffusivity of pure copper at liquid helium temperatures makes possible very important advances in the absolute accuracy, reproducibility, sensitivity, and time constant of cryogenic electrical substitution radiometers (ESRs), relative to conventional ESRs. The design and characterization of a table top cryogenic ESR now available for detector calibration work to the 0.01% level of absolute accuracy under laser illumination is discussed. A sensitive cryogenic ESR recently deliv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
41
0

Year Published

1995
1995
2023
2023

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 62 publications
(42 citation statements)
references
References 3 publications
1
41
0
Order By: Relevance
“…The temperature increase of an irradiated cavity cooled to liquid helium temperatures is compared by a null method with the temperature increase caused by deposition of accurately measured electrical power into an equivalent cavity. Although corrections for reflections, scattering and diffraction must be made, cryogenic radiometers are accepted as the most accurate radiometric standards (Fox and Martin 1990;Foukal et al 1990;Hoyt and Foukal 1991;Quinn and Martin 1991a, b).…”
Section: Primary Radiometric Standardsmentioning
confidence: 99%
“…The temperature increase of an irradiated cavity cooled to liquid helium temperatures is compared by a null method with the temperature increase caused by deposition of accurately measured electrical power into an equivalent cavity. Although corrections for reflections, scattering and diffraction must be made, cryogenic radiometers are accepted as the most accurate radiometric standards (Fox and Martin 1990;Foukal et al 1990;Hoyt and Foukal 1991;Quinn and Martin 1991a, b).…”
Section: Primary Radiometric Standardsmentioning
confidence: 99%
“…The radiance on the integrating sphere was calibrated using the TACR 9 . The TACR is a cryogenically cooled active cavity radiometer that works on the principle of electrical substitution heating 10 . The TACR has been fitted with the same fore-optics as the CERES flight instruments to minimize the errors caused by mismatched field of views and aperture areas.…”
Section: Radiometric Calibration Facility (Rcf)mentioning
confidence: 99%
“…This ECPR radiometer is traceable to our absolute cryogenic radiometer [7]. Four tunable laser diodes covering the range between 1250-1650 nm were used in a calibration setup similar to the one used in reference [12]. At 850 nm a multimode laser diode has been used.…”
Section: 3-spatial Non-uniformity Of Responsementioning
confidence: 99%