Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a feasibility study

Abstract: Cryoballoon ablation is safe and feasible under RT 3D TEE guidance. This imaging tool permits perfect visualization of all PV ostia and neighbouring LA structures. Most importantly, it proved very efficient in guiding the operator to achieve complete occlusion and successful isolation in all veins.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
16
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 27 publications
0
16
0
Order By: Relevance
“…Considering most complications are nearly all caused by incorrect puncture site (13), TEE can provide more benefit even when using biplane fluoroscopy. TEE not only 3D TEE allows real-time visualization of pulmonary vein anatomy, as well as of all surrounding atrial structures (14). It permits online monitoring of balloon positioning and pulmonary vein occlusion via color Doppler, which guides the operator to perform every step of the procedure in a safe manner and might improve both safety and efficacy of the procedure.…”
Section: Discussionmentioning
confidence: 99%
“…Considering most complications are nearly all caused by incorrect puncture site (13), TEE can provide more benefit even when using biplane fluoroscopy. TEE not only 3D TEE allows real-time visualization of pulmonary vein anatomy, as well as of all surrounding atrial structures (14). It permits online monitoring of balloon positioning and pulmonary vein occlusion via color Doppler, which guides the operator to perform every step of the procedure in a safe manner and might improve both safety and efficacy of the procedure.…”
Section: Discussionmentioning
confidence: 99%
“…[44][45][46] It might also play a role in both surgical plans and ablation guidance, especially for the ventricular tachycardia and ventricular arrhythmia. 28,[47][48][49]…”
Section: Discussionmentioning
confidence: 99%
“…12.16) [109][110] [111]. Recently, RT3D TEE has been demonstrated in several clinical studies to provide superior 3D visualization of all pulmonary vein ostia and neighboring left atrial structures during ablation and to provide the operator successful guidance to position an ablation c atheter or cryoballoon in the pulmonary veins [112] [113] [114].…”
Section: Electrophysiological Proceduresmentioning