2018 Joint Conference - Acoustics 2018
DOI: 10.1109/acoustics.2018.8502426
|View full text |Cite
|
Sign up to set email alerts
|

Crosstalk Effect in Medical Ultrasound Tomography Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…The neighboring elements "1", "-1", "2", "-2", "3" and "-3" are connected individually to a digital oscilloscope, displaying the parasitic voltage generated on each element (V i , i = 1,-1, 2,-2, 3, and -3). In the literature [11,14] the crosstalk level C (dB) is evaluated from the measurements using the relation (1):…”
Section: Crosstalk Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…The neighboring elements "1", "-1", "2", "-2", "3" and "-3" are connected individually to a digital oscilloscope, displaying the parasitic voltage generated on each element (V i , i = 1,-1, 2,-2, 3, and -3). In the literature [11,14] the crosstalk level C (dB) is evaluated from the measurements using the relation (1):…”
Section: Crosstalk Measurementsmentioning
confidence: 99%
“…The major objective of ongoing and future research in this area is to optimize the electroacoustic performance of these transducers, to obtain a high image resolution for more reliable and safe diagnostics. For this purpose, several works investigate the crosstalk phenomenon, which decreases the performance of the ultrasonic transducer arrays [6][7][8][9][10][11][12][13][14]. Indeed, when one element of a transducer array is driven, it generates parasitic voltages and/or displacement fields on the passive neighboring elements, which affects the performance of these devices.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The first one proposes improvements at the level of design and manufacture of the transducer arrays. It investigates the geometry and dimensions of the kerf filling material [19][20] particularly, the optimization of the front matching layers [21][22][23] and the improvement of the Printed Circuit Board (PCB) are utilized to connect the transducer array elements [24][25]. The second method is based on corrective electrical excitations applied to the array's elements to minimize the parasitic displacements and thus reducing crosstalk [26][27][28][29].…”
Section: Introductionmentioning