2018 IEEE Electrical Design of Advanced Packaging and Systems Symposium (EDAPS) 2018
DOI: 10.1109/edaps.2018.8680903
|View full text |Cite
|
Sign up to set email alerts
|

Crosstalk and EMI Reduction using enhanced Guard Trace Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…The elements in CTL-CTM in the complex interconnection structure can be accurately obtained using Formula (8). However, matrix solution and further crosstalk cancellation circuit implementation will be complex.…”
Section: Determination Of Ctl-ctm Elementmentioning
confidence: 99%
See 1 more Smart Citation
“…The elements in CTL-CTM in the complex interconnection structure can be accurately obtained using Formula (8). However, matrix solution and further crosstalk cancellation circuit implementation will be complex.…”
Section: Determination Of Ctl-ctm Elementmentioning
confidence: 99%
“…In electrical interconnection, microstrip lines are often used as interconnection structures. Crosstalk between microstrip lines is extensively investigated, but most of the studies focus on crosstalk analysis or crosstalk-reduction design between parallel microstrip lines [5][6][7][8]. However, in an actual interconnection design, there is few scenarios in which only parallel microstrip lines are used for layout design.…”
Section: Introductionmentioning
confidence: 99%
“…3 Although this method has a good ability to improve crosstalk, it wastes limited wiring space and does not conform to the development direction of integration. In the articles, [4][5][6] the crosstalk is improved by placing a via-stitch guard or a serpentine guard trace between multiple transmission lines, and the effect of improving the crosstalk is analyzed by EM simulation. The complex structure and possible resonance problems of this method make it difficult to apply and generalize this method in practice.…”
Section: Introductionmentioning
confidence: 99%
“…At present, scholars are conducting extensive research on crosstalk reduction [5][6][7][8]. For example, crosstalk can be reduced by protective wiring, serpentine microstrip lines, step-shaped transmission lines, and other methods.…”
Section: Introductionmentioning