Critical review of the analysis of non- and mono-ortho-chlorobiphenyls

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
34
0
12

Year Published

1997
1997
2010
2010

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 87 publications
(46 citation statements)
references
References 194 publications
0
34
0
12
Order By: Relevance
“…The result showed that increasing the amount of AgNO 3 silica in the multi-layer silica column would strengthen the retention of PBDEs to a larger extent than those of PCBs and PCDD/Fs. Moreover, AgNO 3 silica was found to be a very efficient sulphur removing agent [18][19][20]. Considering both the performance and cost, multi-layer silica columns with 2 g AgNO 3 silica was more preferable.…”
Section: Separation Of Pbdes From Pcbs and Pcdd/fs Using Multi-layer mentioning
confidence: 99%
See 1 more Smart Citation
“…The result showed that increasing the amount of AgNO 3 silica in the multi-layer silica column would strengthen the retention of PBDEs to a larger extent than those of PCBs and PCDD/Fs. Moreover, AgNO 3 silica was found to be a very efficient sulphur removing agent [18][19][20]. Considering both the performance and cost, multi-layer silica columns with 2 g AgNO 3 silica was more preferable.…”
Section: Separation Of Pbdes From Pcbs and Pcdd/fs Using Multi-layer mentioning
confidence: 99%
“…Activated carbon chromatography columns with toluene have been widely used in the separation of PCBs and PCDD/Fs [18]. However, the performance of activated carbon chromatography column was found to be inconsistent due to the inconsistent sorbent packing.…”
Section: Separation Of Pcbs From Pcdd/fs Using a Small Florisil Columnmentioning
confidence: 99%
“…The SPH Analytical Laboratory is accredited by the Clinical Laboratory Evaluation Program of the New York State Department of Health. The quality assurance/quality control program for the laboratory was developed in accordance with recommendations in relevant publications (Brock et al 1996;Greizerstein et al 1997;Hess et al 1995).…”
Section: Methodsmentioning
confidence: 99%
“…Dioxin-like PCBs (DL-PCBs) are often analysed together with dioxins and furans by gas chromatography-high resolution mass spectrometry (GC-HRMS). For this purpose, DL-PCBs are separated from other PCB congeners as part of the clean-up and fractionation process, for example using activated carbon, porous graphite columns, or 2-(1-pyrenyl) ethyldimethylsilyated (PYE) silica (Hess et al, 1995).…”
Section: Analytical Toolsmentioning
confidence: 99%