2017
DOI: 10.1016/j.cryogenics.2017.05.002
|View full text |Cite
|
Sign up to set email alerts
|

Critical current measurement of commercial REBCO conductors at 4.2 K

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
2
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 64 publications
(41 citation statements)
references
References 21 publications
1
37
2
1
Order By: Relevance
“…Remarkably high critical current values of 2247 and 2119 A/4 mm width have been measured at 4.2 K, 14 T for the two samples. These values are higher by a factor of >2 than the best reported value in 3.2 μm thick, 20 mol% Zr added GdYBCO film processed in three passes using conventional MOCVD and more than five times higher than the commercial HTS tapes reported in a recent study [35,43].…”
Section: Resultscontrasting
confidence: 59%
“…Remarkably high critical current values of 2247 and 2119 A/4 mm width have been measured at 4.2 K, 14 T for the two samples. These values are higher by a factor of >2 than the best reported value in 3.2 μm thick, 20 mol% Zr added GdYBCO film processed in three passes using conventional MOCVD and more than five times higher than the commercial HTS tapes reported in a recent study [35,43].…”
Section: Resultscontrasting
confidence: 59%
“…More values and physical discussions can be found in [56]. Values measured at SPC, from [53] and from [54]. Variations from production runs cab be up to 50%.…”
Section: Coated Conductors (Rebco)mentioning
confidence: 96%
“…The critical current of commercial coated conductors covers a wide range of values, from about 100 A to over 250 A at 77 K, self-field (for a 4 mm wide tape). Also at low temperature, in field, the range covers almost a factor 7: a glimpse of the situation is plotted in figure 3 for various tapes measured in the last five years at the Swiss Plasma Center, together with recent values from [53] and [54]; the reader can find more characteristics and specifications in [52]. In order to improve the critical current values in field some manufacturers add artificial pinning centres (APC) in the ceramic layer; this technique was first introduced by SuperPower, adding…”
Section: Coated Conductors (Rebco)mentioning
confidence: 97%
“…要实现高效成材和产业化制备, 必须解决MOD法的 热解时间过长的问题 [14,22] . Figure 2 (Color online) Effect of gas flow rate on nucleation potential and orientation of MOD thin film growth [22][23][24][25] ), 除此之外, 还有面内其他缺陷的贡献 [26,27] .…”
Section: 然而 要实现长带上的产业化制备 Mod工业似unclassified