2018
DOI: 10.1007/s10337-018-3640-z
|View full text |Cite|
|
Sign up to set email alerts
|

Critical Comparison of Liquid Chromatography Coupled to Mass Spectrometry and Three Different Ion Mobility Spectrometry Systems on Their Separation Capability for Small Isomeric Compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 18 publications
0
7
0
1
Order By: Relevance
“…This example shows that the sole use of additives in the drift gas is likely not sufficient to separate isomers. This finding is supported by a comparative study in which directly infused steroid hormones, using different ion mobility instruments and SR (DMA with acetonitrile and DMS with 2-propanol), showed no difference in resolution with the use of additives ( Werres et al, 2019 ).…”
Section: Ims-ms Approaches Towards the Separation Of Geometrical Lipi...mentioning
confidence: 70%
“…This example shows that the sole use of additives in the drift gas is likely not sufficient to separate isomers. This finding is supported by a comparative study in which directly infused steroid hormones, using different ion mobility instruments and SR (DMA with acetonitrile and DMS with 2-propanol), showed no difference in resolution with the use of additives ( Werres et al, 2019 ).…”
Section: Ims-ms Approaches Towards the Separation Of Geometrical Lipi...mentioning
confidence: 70%
“…As already demonstrated for the combination of LC and IM‐MS, the CE separation through the measurement of the effective mobility values ( μ eff ) appeared to be more powerful than the IM separation [31]. For isomeric analytes and due to the strong correlation of CCS with m/z , most of the isomers could not be distinguished by their CCS (relative CCS difference <2%).…”
Section: Resultsmentioning
confidence: 99%
“…The separation of isomers usually requires high IMS resolving power due to the minimal structural differences that are often associated with isomeric ions in gas phase (Causon & Hann, 2015; Kaufmann et al, 2020; Werres et al, 2019) (Table 1).…”
Section: Im‐ms To Separate Metabolites and Lipidsmentioning
confidence: 99%
“…The separation of isomers usually requires high IMS resolving power due to the minimal structural differences that are often associated with isomeric ions in gas phase (Causon & Hann, 2015;Kaufmann et al, 2020;Werres et al, 2019) (Table 1). Hofmann et al (2015) reported the IMS separation of six trisaccharide isomers that differed in composition, connectivity, or configuration.…”
Section: Isomers Separationmentioning
confidence: 99%