2019
DOI: 10.1016/j.trac.2019.115688
|View full text |Cite
|
Sign up to set email alerts
|

Critical assessment of recent trends related to screening and confirmatory analytical methods for selected food contaminants and allergens

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
58
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 70 publications
(61 citation statements)
references
References 97 publications
3
58
0
Order By: Relevance
“…Two recent review papers have extensively outlined commercially-available and proof-of-concept single-plex and multiplex allergen immunoassays and biosensors, and the assays reported in this study have matched or surpassed these previously-reported LODs [9,51]. All the developed multiplex assays were able to detect both analytes in the low ppm range within minutes.…”
Section: Discussionsupporting
confidence: 60%
See 1 more Smart Citation
“…Two recent review papers have extensively outlined commercially-available and proof-of-concept single-plex and multiplex allergen immunoassays and biosensors, and the assays reported in this study have matched or surpassed these previously-reported LODs [9,51]. All the developed multiplex assays were able to detect both analytes in the low ppm range within minutes.…”
Section: Discussionsupporting
confidence: 60%
“…Additionally, the PHC assay was validated as a screening method in spiked matrix extract, blank matrix extract (n = 20) and incurred spiked flour, proving its capability of detecting the target even in complex matrices. The majority of commercially-available allergen detection LFIA test kits can detect a single analyte at 1-10 ppm [9,51]. Comparatively, PHC was able to detect both analytes at 0.5 ppm of THP and TPP spiked into a blank biscuit matrix extract, affirming its place as one of the most sensitive allergen LFIAs.…”
Section: Discussionmentioning
confidence: 79%
“…However, AChE activity is reduced in the presence of CMs or OPs, due to carbamylation or phosphorylation of serine hydroxyl group in the enzyme active cite [3], respectively. This results in acetylcholine accumulation, which can Liquid and/or gas chromatography tandem mass spectrometry (LC-MS/MS and/or GC-MS/MS) are commonly applied for pesticide residues monitoring in food matrices [8]. Although these methods provide selectivity, sensitivity with high-throughput capabilities, LC/MS and GC/MS are also costly and time-consuming methodologies that require skilled personnel [9].…”
Section: Introductionmentioning
confidence: 99%
“…During assay optimization, various parameters were investigated including a critical comparison of commonly applied AChE substrates for the first time. Following our recently published paper, which addressed the issues related to the validation and benchmarking of biosensors in food safety [8], comprehensive validation datasets for carbofuran, carbofuran-3-hydroxy and dichlorvos in strawberry and lettuce extracts are presented. The optimized AChE assay was benchmarked towards an accredited LC-MS/MS method, following the regulatory requirement (Decision 2002/657/EC) of confirming bioassays results with an instrumental method.…”
Section: Introductionmentioning
confidence: 99%
“…Malachite green and its metabolites are toxic, mutagenic, and carcinogenic. A number of studies have been described for the determination of antibiotics, malachite green, and leucomalachite green in different sample treatment methods and instrumental determination methods [15][16][17][18]. However, these methods are focused only on single-drug class of veterinary residues, which leads to low efficiency and high cost when different physicochemical properties of various veterinary drugs are determined separately.…”
Section: Introductionmentioning
confidence: 99%